首页> 外文期刊>Australasian physical & engineering sciences in medicine >Acceptance testing and commissioning of Kodak Directview CR-850 digital radiography system
【24h】

Acceptance testing and commissioning of Kodak Directview CR-850 digital radiography system

机译:柯达Directview CR-850数字放射成像系统的验收测试和调试

获取原文
获取原文并翻译 | 示例
           

摘要

This Technical Paper describes Acceptance Testing and Commissioning of the Kodak DirectView CR-850 digital radiography system installed at the Royal Adelaide Hospital. The first of its type installed in Australia, the system is a "dry" image processor, for which no chemicals are required to develop images. Rather, latent radiographic images are stored on photostimulable phosphor screens, which are scanned and displayed by a reader unit. The image can be digitally processed and enhanced before it is forwarded to a storage device, printer or workstation display, thereby alleviating the need to re-expose patients to achieve satisfactory quality images. The phosphor screens are automatically erased, ready for re-use. Results are reported of tests carried out using the optional "Total Quality Tool" quality assurance package installed with the system. This package includes analysis and reporting software which provides for simple testing and reporting of many important characteristics of the system, such as field uniformity, aspect ratio, line and pixel positions, image and system noise, exposure response, scan linearity, modulation transfer function (MTF) and image artefacts. Acceptance Tests were performed for kV and MV exposures. Resolution for MV exposures was at least 0.8 l/mm, and measured phantom dimensions were within 1.05% of expected magnification. Reproducibility between cassettes was within 1.6%. The mean pixel values on the central axis were close to linear for MV exposures from 3 to 10 MU and reached saturation level at around 20 MU for 6 MV and around 30 MV for 23 MV beams. Noise levels were below 0.2%.
机译:本技术文件介绍了皇家阿德莱德医院安装的柯达DirectView CR-850数字放射成像系统的验收测试和调试。该系统在澳大利亚首次安装,是“干式”图像处理器,不需要化学药品即可显影图像。而是将射线照相潜像存储在可光激发的荧光屏上,并由阅读器对其进行扫描和显示。在将图像转发到存储设备,打印机或工作站显示器之前,可以对其进行数字处理和增强,从而减轻了对患者重新曝光以获得满意质量图像的需要。磷光屏会自动擦除,以备再次使用。报告使用安装在系统中的可选“ Total Quality Tool”质量保证程序包进行的测试结果。该软件包包括分析和报告软件,可对系统的许多重要特征进行简单的测试和报告,例如场均匀性,纵横比,行和像素位置,图像和系统噪声,曝光响应,扫描线性度,调制传递函数( MTF)和图像伪像。对kV和MV暴露进行了验收测试。 MV曝光分辨率至少为0.8 l / mm,测得的幻像尺寸在预期放大倍率的1.05%以内。盒之间的重现性在1.6%以内。对于从3到10 MU的MV曝光,中心轴上的平均像素值接近线性,对于6 MV和23 MV光束,在20 MU左右达到饱和水平,在30 MV左右达到饱和水平。噪音水平低于0.2%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号