This study aimed to quantify the amount of change in Standardised Uptake Values (SUVs) of PET/CT images by simulating the set-up as closely as possible to the actual patient scanning. The experiments were conducted using an anthropomorphic phantom, which contained an amount of radioactivity in the form of Fluorodeoxyglucose (FDG) in a primary plastic test tube and one litre saline bags, including the insertion of bony structures and another two test tubes containing different concentrations of iodine contrast media. Standard scanning protocols were employed for the PET/CT image acquisition. The highest absolute differences in the SUVmax and SUVmean values of the saline bags were found to be about 0.2 and 0.4, respectively. The primary test tube showed the largest change of 1.5 in both SUVs; SUV max and SUVmean. However, none of these changes were found to be statistically significant. The clinical literature also contains no evidence to suggest that the changes of this magnitude would change the final diagnosis. Based on these preliminary data, we propose that iodine contrast media can be used during the CT scan of PET/CT imaging, without significantly affecting the diagnostic quality of this integrated imaging modality.
机译:这项研究旨在通过模拟尽可能接近实际患者扫描的设置来量化PET / CT图像标准摄取值(SUV)的变化量。实验是使用拟人化体模进行的,该体模在初级塑料试管和一升生理盐水袋中包含一定量的氟脱氧葡萄糖(FDG)形式的放射性,包括插入骨结构和另外两个包含不同浓度的放射性试管。碘造影剂。 PET / CT图像采集采用标准扫描协议。盐水袋的SUVmax和SUVmean值的最大绝对差分别约为0.2和0.4。初级试管在两种SUV中的变化最大,为1.5。 SUV max和SUVmean。但是,这些变化均未发现有统计学意义。临床文献也没有证据表明这种幅度的变化会改变最终的诊断。基于这些初步数据,我们建议可以在PET / CT成像的CT扫描过程中使用碘造影剂,而不会显着影响这种集成成像方式的诊断质量。

著录项

  • 来源
  • 作者单位

    Discipline of Medical Radiations, School of Medical Sciences,Bundoora West Campus, RMIT University, VIC 3083, Australia;

    Nuclear Imaging Centre, Faculty of Medicine and Health Sciences, University Putra Malaysia (UPM), 43400 Serdang,Malaysia;

    William Buckland Radiotherapy Centre, The Alfred Hospital,P.O. Box 315, Prahran, VIC 3181, Australia;

    Nuclear Medicine Department, The Alfred Hospital,P.O. Box 315, Prahran, VIC 3181, Australia;

    Nuclear Medicine Department, The Alfred Hospital,P.O. Box 315, Prahran, VIC 3181, Australia;

    Discipline of Medical Radiations, School of Medical Sciences,Bundoora West Campus, RMIT University, VIC 3083, Australia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    pet/ct; iodine contrast media; suvmax; suvmean;

    机译:宠物/ ct;碘造影剂;suvmax;硫;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号