首页> 外文期刊>Australasian physical & engineering sciences in medicine >Estimation of adult patient doses for common diagnostic X-ray examinations in Wad-madani, Sudan: derivation of local diagnostic reference levels
【24h】

Estimation of adult patient doses for common diagnostic X-ray examinations in Wad-madani, Sudan: derivation of local diagnostic reference levels

机译:苏丹Wad-madani的成人诊断X射线检查成人患者剂量估计:局部诊断参考水平的推导

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The objectives of this study were to estimate patient dose in some common diagnostic X-ray examinations. Radiation doses were estimated for 307 patients in six public hospitals comprising 7 X-ray units in Wad-madani, Sudan. Entrance surface air kerma (ESAK) was estimated in a three step protocol: First, X-ray unit output Y(d) was measured at a distance, d for different peak tube voltages and tube loadings (mAs). Next, incident air kerma (K_i) was calculated from Y(d) using inverse square law combined with patient exposure factors. ESAK was calculated from K_i using backscatter factor, B. Mean ESAK values are comparable to those reported in other countries and are below reference dose levels. The estimated mean ESAK values are: 0.3, 2.2, 2.2, 2.9, 2.8, 3.1, and 7.5 mGy for chest PA, Skull AP/PA, Skull LAT, Abdomen, Pelvis AP, Lumbar Spine AP and Lumbar Spine LAT examinations, respectively. The results are used for dose optimization, and to propose local diagnostic reference levels.
机译:这项研究的目的是估计一些常见的X射线诊断检查中的患者剂量。在苏丹Wad-madani的6家公立医院中,估计有307名患者的放射剂量,其中包括7个X射线装置。进气表面空气比释动能(ESAK)可以通过三步协议进行估算:首先,对于不同的峰值管电压和管负载(mAs),在距离d处测量X射线单元的输出Y(d)。接下来,使用平方反比定律和患者暴露因子,由Y(d)计算出空气比释动能(K_i)。 ESAK是使用后向散射因子B由K_i计算得出的。平均ESAK值可与其他国家/地区报告的值相比较,并且低于参考剂量水平。胸部PA,头骨AP / PA,头骨LAT,腹部,骨盆AP,腰椎AP和腰椎LAT检查的估计平均ESAK值分别为:0.3、2.2、2.2、2.9、2.8、3.1和7.5 mG​​y。结果用于剂量优化,并提出局部诊断参考水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号