The WMO Field intercomparison of Rainfall Intensity (RI) Gauges started on October, 1st 2007 at Vigna di Valle (Italy) and was concluded in May 2009. Those catching type instruments, out of the selected rain gauges based on various measuring principles, and the four rain gauges selected as reference instruments to be installed in a pit, were preliminarily calibrated in the laboratory before their final installation at the Field Intercomparison site. The recognized WMO laboratory at the University of Genoa was involved in this task, using the same standard tests adopted for the previously held WMO Laboratory Intercomparison of Rl gauges. Further tests were performed to investigate the one-minute performance of the involved instruments. The present paper deals with basically Tipping-Bucket Rain gauges (TBRs) and Weighing Gauges (WGs), using results from tests performed under constant flow rates in laboratory conditions. The objective of this initial phase of the Intercomparison was to single out the counting errors associated with each instrument, so as to help the understanding of the measured differences between instruments in the field during the second phase. Results and comments on the preliminary laboratory calibration exercise are reported in this paper together with their implications for the analysis of the outcome of the Intercomparison in the Field.
机译:WMO雨量仪(RI)现场比对于2007年10月1日在意大利的Vigna di Valle开始,并于2009年5月结束。这些捕集型仪器是根据各种测量原理从选定的雨量仪中选出的,在现场比对现场进行最终安装之前,已在实验室中初步校准了四个被选为安装在坑中的雨量计作为参考仪器。热那亚大学公认的WMO实验室参与了这项任务,使用的是以前举行的WMO Rl仪表比对实验室采用的相同标准测试。进行了进一步的测试以调查所涉及仪器的一分钟性能。本文使用在实验室条件下以恒定流量执行的测试结果,主要介绍了自卸车雨量计(TBR)和称重计(WGs)。比较的初始阶段的目的是找出与每种仪器相关的计数误差,以帮助理解第二阶段现场仪器之间的测量差异。本文报告了实验室初步校准工作的结果和意见,以及它们对现场比对结果分析的意义。

著录项

  • 来源
    《Atmospheric research》 |2009年第4期|555-563|共9页
  • 作者

    Luca G. Lanza; L. Stagi;

  • 作者单位

    DICAT - Dept. of Construction, Environmental and Territorial Engineering, University of Genova, 1 Montallegro - 16145 Genoa, Italy;

    DICAT - Dept. of Construction, Environmental and Territorial Engineering, University of Genova, 1 Montallegro - 16145 Genoa, Italy;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    precipitation; measurement; calibration; laboratory; WMO;