首页> 外文期刊>ASHRAE Transactions >Effect Of Temperature Stratification Near Heating Elements On The Measured Energy Factors Of Electric Water Heaters
【24h】

Effect Of Temperature Stratification Near Heating Elements On The Measured Energy Factors Of Electric Water Heaters

机译:加热元件附近的温度分层对电热水器测得的能量因数的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Two different models of 190 L (50 gallon) residential electric water heaters were tested to investigate problems that arise in determining their energy efficiencies due to the steep temperature gradient near the lower heating element. This gradient makes the determination of the average tank water temperature difficult because, in accordance with current test standards, temperature measurements are made at only six discrete locations within the water heater. Results show that errors in determining this average temperature can have significant effects on the Energy Factor by yielding inaccurate estimates of the stored energy within the tank. This estimate of the stored energy is part of the correction algorithm used to normalize the lab measured efficiency to the standard conditions that define the Energy Factor. The investigation 's findings suggest that efforts should be made to ensure that conditions at the start of a test are similar to those at the end. For the two water heaters tested here, this scenario was best achieved by starting with a 24 hour idling period.
机译:测试了两种不同型号的190 L(50加仑)家用电热水器,以调查由于下部加热元件附近的陡峭温度梯度而在确定其能源效率时出现的问题。该梯度使确定罐内平均水温变得困难,因为根据当前的测试标准,仅在热水器内的六个离散位置进行温度测量。结果表明,确定该平均温度的错误可能会对储罐中存储的能量产生不正确的估计,从而对能量因数产生重大影响。所存储能量的此估计是用于将实验室测得的效率标准化为定义能量因数的标准条件的校正算法的一部分。调查的结果表明,应努力确保测试开始时的条件与结束时的条件相似。对于此处测试的两个热水器,从24小时空转期开始可以最好地实现这种情况。

著录项

  • 来源
    《ASHRAE Transactions》 |2008年第2期|85-95|共11页
  • 作者

    W.M. Healy;

  • 作者单位
  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 00:43:23

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号