This paper provides several metrics to characterize the efficiency of data centers. Power Usage Effectiveness (PUE) measures the fraction of the total facility power devoted to IT work. Compute Power Efficiency (CPE) measures the overall efficiency of the data center, considering both power and cooling and the utilization of the data center IT equipment. The paper describes several surveys characterizing PUE for en ter-prise data centers. Based on the data collected to-date, a PUE of 2.0 is expected for a world-class facility. In the near future, data center IT power consumption is likely vary more dramatically in response to workload changes as IT hardware power management technologies are adopted broadly. Data center power and cooling infrastructure must be designed with such variation in mind so that the overall efficiency is not impacted. A simple data center infrastructure and energy cost model is presented to exposes the dramatic change in the relative importance of hardware costs to infrastructure and energy costs. Accurate models capturing these costs must be considered by organizations seeking leadership IT cost structures.
机译:本文提供了一些指标来表征数据中心的效率。电力使用效率(PUE)衡量专用于IT工作的设施总功率的一部分。计算电源效率(CPE)衡量数据中心的整体效率,同时考虑电源和散热以及数据中心IT设备的利用率。本文介绍了表征企业数据中心PUE的几项调查。根据迄今为止收集的数据,世界一流设施的PUE预计为2.0。在不久的将来,随着IT硬件电源管理技术的广泛采用,数据中心IT功耗可能会随着工作负载的变化而发生更大的变化。数据中心的电源和冷却基础架构在设计时必须考虑到这种变化,以免影响整体效率。提出了一个简单的数据中心基础架构和能源成本模型,以揭示硬件成本对基础架构和能源成本的相对重要性的巨大变化。寻找领导IT成本结构的组织必须考虑捕获这些成本的准确模型。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号