An analytical study is carried out to assess the impact of corrections to nominal test conditions on the measured energy factor for residential water heaters. While test conditions are specified in the method of test, the difficulty in exactly achieving these test conditions in the laboratory necessitates a computational approach to correct the results to nominal conditions. This paper examines the magnitude of those corrections for a range of water heaters of various fuel type, heating method, and size across a number of potential draw volumes during a 24-hour simulated use test. In making these corrections, a recovery efficiency and a standby heat loss coefficient are determined during the test; the effects of variations in those measured values on the resultant energy factor are discussed. Finally, the impact of tighter test tolerances on the variability of the energy factor is investigated to assist in evaluating the benefits of changing test conditions.
机译:进行了一项分析研究,以评估对名义测试条件的修正对家用热水器所测得的能量因数的影响。尽管在测试方法中指定了测试条件,但要在实验室中准确达到这些测试条件的困难,需要一种计算方法来将结果校正为名义条件。本文研究了在24小时的模拟使用测试中,各种燃料类型,加热方法和尺寸的热水器在许多潜在吸水量上的修正量。在进行这些校正时,在测试过程中要确定恢复效率和待机热损失系数;讨论了这些测量值的变化对所得能量因数的影响。最后,研究了更严格的测试公差对能量因数可变性的影响,以帮助评估改变测试条件的好处。

著录项

  • 来源
    《ASHRAE Transactions》 |2017年第2期|110-125|共16页
  • 作者

    W.M. Healy;

  • 作者单位

    Energy and Environment Division, National Institute of Standards and Technology, Gaithersburg, MD.;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号