首页> 外文期刊>ASHRAE Transactions >Model-Based Home Envelope Performance Evaluation: A Use Case of Data from Connected Thermostats
【24h】

Model-Based Home Envelope Performance Evaluation: A Use Case of Data from Connected Thermostats

机译:基于模型的家庭信封性能评估:连接的恒温器数据的使用案例

获取原文
获取原文并翻译 | 示例
       

摘要

Envelope performance audits are becoming increasingly important for achieving energy-efficient homes. A model-based envelope performance evaluation method is proposed to evaluate the thermal properties and air-tightness of a house using 10-day measurements of its indoor and outdoor temperatures and HVAC on/ off status. Through a test using data from 1,676 homes provided by a smart thermostat manufacturer), a distinctive correlation between home age and home envelope performance deterioration identified by the proposed method was found, which aligned well with expectations. Although more tests with knowledge of the ground truth of the home envelope condition are needed, the proposed method is shown to be promising.
机译:信封性能审核对于实现节能住宅越来越重要。提出了一种基于模型的包络性能评估方法,该方法通过使用10天的室内和室外温度以及HVAC开关状态来评估房屋的热性能和气密性。通过使用智能恒温器制造商提供的1676所房屋的数据进行的测试,发现该建议方法确定的房屋年龄与房屋围护结构性能下降之间存在明显的相关性,与预期相符。尽管需要更多的关于家庭围护条件的地面真实性知识的测试,但是所提出的方法被证明是有前途的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号