This paper discusses results from ASHRAE Research Project RP-1408, which includes tests to quantify the effect of length on the insertion loss of fiberglass-lined round ducts. The results of insertion loss tests are presented for 1 and 2 in. (25 and 50 mm) thick fiberglass-lined round ducts. Further, an analysis of this data with the objective to develop empirical equations to predict the insertion loss is discussed. The equations are presented and compared with prediction methods currently recommended by ASHRAE Handbook-HVAC Applications.
机译:本文讨论了ASHRAE研究项目RP-1408的结果,其中包括量化长度对玻璃纤维衬里圆形导管插入损耗的影响的测试。给出了1英寸和2英寸(25毫米和50毫米)厚的玻璃纤维内衬圆形导管的插入损耗测试结果。此外,讨论了以开发经验方程以预测插入损耗为目标的对此数据的分析。该方程式已提出,并与ASHRAE Handbook-HVAC Applications当前推荐的预测方法进行了比较。