A new system was developed for measuring AC current distributions in high T/sub c/ superconducting tapes under an external AC magnetic field. In our measurement the current distributions are indirectly found from the results of the self-field distributions measured by an array of pickup coils located around the tape. For improved measurement accuracy under the external magnetic field, a compensation coil was used to cancel the component of the external magnetic field from the signal of pickup coil. In order to confirm the validity of this system, measurement of current distributions in a test conductor composed of insulated copper wires was carried out under an external AC magnetic field. Using this system, we measured the current distributions in multifilamentary Ag alloy sheathed Bi-2223 tape as a function of the angle of the external AC magnetic field at 77 K. Further, we investigated the characteristics of the current distributions for the case of a simultaneous application of AC transport current and transverse AC magnetic field. On the basis of the obtained results the practicality of our measurement system is discussed.
机译:开发了一种新系统,用于在外部交流磁场下测量高T / sub c /超导带中的交流电流分布。在我们的测量中,电流分布是从位于磁带周围的拾波线圈阵列测量的自场分布结果中间接找到的。为了提高外部磁场下的测量精度,使用了补偿线圈从拾波线圈的信号中消除了外部磁场的分量。为了确认该系统的有效性,在外部交流磁场下对由绝缘铜线组成的测试导体中的电流分布进行了测量。使用该系统,我们测量了多丝银合金铠装Bi-2223胶带中的电流分布,该电流分布是在77 K时外部交流磁场的角度的函数。此外,我们研究了同时存在的情况下电流分布的特性交流输运电流和横向交流磁场的应用。基于获得的结果,讨论了我们的测量系统的实用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号