This paper presents the results of a comparison study of the internal forces applied to the structure due to wind load determined based on SNI 1727: 2013 that is inputted manually and automatically using ASCE 7-10 wind load feature in SAP2000. The wind load reviewed in this study is the wind load that calculated by following the Directional Procedure stated in SNI 1727:2013. The study shows that the wind load calculated based on SNI 1727:2013 when the internal pressure coefficient GCpi is defined as 0.18 is 12% higher than the wind load calculated automatically by applying ASCE 7-10 wind load feature provided by SAP2000 when the wind parameters are assigned based on SNI 1727:2013.
机译:本文介绍了对根据SNI 1727:2013确定的风荷载施加到结构上的内力进行比较研究的结果,SNI 1727:2013是使用SAP2000中的ASCE 7-10风荷载功能手动和自动输入的。在这项研究中审查的风荷载是按照SNI 1727:2013中规定的定向程序计算的风荷载。研究表明,当将内部压力系数GCpi定义为0.18时,根据SNI 1727:2013计算的风载荷比应用SAP2000提供的ASCE 7-10风载荷功能在风参数为20%时自动计算的风载荷高12%。根据SNI 1727:2013分配。