An experimental investigation was undertaken in which the thermal resistance for the heat flow through a typical timber framed pitched roofing system was measured under outdoor conditions for heat flow up. The measured thermal resistance of low resistance systems such as an uninsulated attic space and a reflective attic space compared well with published data. However, with higher thermal resistance systems containing bulk insulation within the timber frame, the measured result for a typical installation was as low as 50% of the thermal resistance determined considering two dimensional thermal bridging using the parallel path method. This result was attributed to three dimensional heat flow and insulation installation defects, resulting from the design and construction method used. Translating these results to a typical house with a 200 m~2 floor area, the overall thermal resistance of the roof was at least 23% lower than the overall calculated thermal resistance including two dimensional thermal bridging. When a continuous layer of bulk insulation was applied to the roofing system, the measured values were in agreement with calculated resistances representing a more reliable solution.
机译:进行了一项实验研究,在该条件下,在室外条件下测量了通过典型木框斜屋顶系统的热流的热阻。低电阻系统(例如非绝缘的阁楼空间和反射式阁楼空间)的测量热阻与已发布的数据进行了很好的比较。但是,对于在木框架内包含大量绝热材料的较高热阻系统,典型安装的测量结果低至考虑到使用并行路径法进行二维热桥接的热阻的50%。该结果归因于三维热流和绝热装置的缺陷,这是由于所使用的设计和构造方法引起的。将这些结果转换成具有200 m〜2的典型房屋面积后,屋顶的总热阻比包括二维热桥接的总计算热阻低至少23%。将连续的大块绝缘层应用于屋顶系统时,测量值与代表更可靠解决方案的计算电阻相符。

著录项

  • 来源
    《Applied Energy》 |2011年第1期|p.127-137|共11页
  • 作者

    M. Belusko; F. Bruno; W. Saman;

  • 作者单位

    Institute for Sustainable Systems and Technologies, University of South Australia, Mawson Lakes Boulevard, SA 5095, Australia;

    Institute for Sustainable Systems and Technologies, University of South Australia, Mawson Lakes Boulevard, SA 5095, Australia;

    Institute for Sustainable Systems and Technologies, University of South Australia, Mawson Lakes Boulevard, SA 5095, Australia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    heat transfer; buildings; thermal resistance; timber roof; bulk insulation; reflective foil;

    机译:传热;建筑物;热阻;木材屋顶;隔热;反射箔;
  • 入库时间 2022-08-18 00:10:04

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号