A great portion of the primary energy is consumed by space heating and cooling in buildings. The need for utilizing more renewable energy in the building sector remains critical for ensuring the energy and environment sustainability. Geothermal energy is one of the renewable energy sources that we have an easy access to for supplying low-grade thermal energy with a low impact on the environment. The methods of utilizing geothermal energy for buildings include such as ground source heat pumps and earth to air heat exchangers (EAHEs). In this paper we presented the comprehensive performance analysis and deduced an easy-to-apply regression model for predicting the cooling capacity of an EAHE. A one-dimensional steady-state control volume model was developed and applied to simulate the performance of the EAHE. It couples both heat and mass transfer between the air and the tube. The model was calibrated by comparing against the experimental data from an existing renewable energy testing facility. After the calibration, six factors, namely the air temperature, the air relative humidity, the air velocity at the inlet of EAHE, the tube surface temperature, and the tube length and diameter on the performance were analyzed using the calibrated model. The polynomial regression models for predicting the cooling capacities including total, sensible and latent cooling capacity with high accuracy were obtained. The easy-to-apply formulas can be of great use in the design and application of EAHEs. (C) 2014 Elsevier Ltd. All rights reserved.
机译:建筑物的空间供暖和制冷消耗了大量的一次能源。在建筑部门使用更多可再生能源的需求对于确保能源和环境的可持续性仍然至关重要。地热能是一种可再生能源,我们很容易获得它来提供对环境影响较小的低等级热能。将地热能用于建筑物的方法包括诸如地源热泵和地空气热交换器(EAHE)。在本文中,我们介绍了全面的性能分析,并推导了一种易于应用的回归模型来预测EAHE的冷却能力。开发了一维稳态控制量模型,并将其应用于模拟EAHE的性能。它耦合了空气和管道之间的传热和传质。通过与现有可再生能源测试设施的实验数据进行比较,对模型进行了校准。校准后,使用校准模型分析了空气温度,空气相对湿度,EAHE入口处的空气流速,管表面温度以及管长和管径对性能的六个影响。得到了多项式回归模型,可以高精度地预测冷却能力,包括总的,显着的和潜在的冷却能力。易于应用的公式可以在EAHE的设计和应用中大量使用。 (C)2014 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Applied Energy》 |2015年第1期|211-221|共11页
  • 作者单位

    Univ Nebraska Lincoln, Coll Engn, Durham Sch Architectural Engn & Construct, Omaha, NE 68198 USA;

    Univ Nebraska Lincoln, Coll Engn, Durham Sch Architectural Engn & Construct, Omaha, NE 68198 USA;

    Lawrence Technol Univ, Architectural Engn Dept, Southfield, MI USA;

    Univ Nebraska Lincoln, Coll Engn, Durham Sch Architectural Engn & Construct, Omaha, NE 68198 USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);