首页> 外文期刊>Applied Acoustics >Precision of ISO 3382-2 and ISO 3382-3 - A Round-Robin test in an open-plan office
【24h】

Precision of ISO 3382-2 and ISO 3382-3 - A Round-Robin test in an open-plan office

机译:ISO 3382-2的精度和ISO 3382-3 - 开放式办公室中的循环测试

获取原文
获取原文并翻译 | 示例
       

摘要

International standards ISO 3382-2 and ISO 3382-3 are increasingly applied to determine the room acoustic conditions in open-plan offices because attention to noise control in such workplaces has increased. The precision of those standards in open-plan offices has not been published. The purpose of this study was to determine the precision of ISO 3382-2:2008 and ISO 3382-3:2012 in an open-plan office following the instructions of ISO 5725 standard. Furthermore, the results were analyzed in the light of ISO CD 3382-3:2020 involving improvements related to uncertainty. An accuracy experiment (a.k.a Round-Robin test, inter-laboratory test, intercomparison test) was arranged where nine independent participants conducted the measurements in the same open-plan office. For ISO 3382-3:2012, the reproducibility standard deviations were 0.5 dB, 1.3 dB, 1.3 dB, and 18% for spatial decay rate of speech (D-2,D-S), A-weighted SPL of speech at 4 m distance (L-p,(A, S,4m)), A-weighted SPL of background noise (L-p,L-A,L-B), and distraction distance (r(D)). The corresponding values for ISO CD 3382-3:2020 were 0.3 dB, 1.1 dB, 0.6 dB, and 16%, respectively. The reproducibility standard deviations for reverberation time were 4.5-16% within 1/1-octave bands 125-8000 Hz. The measurement uncertainty of ISO CD 3382-3:2020 is smaller than that of ISO 3382-3:2012. The values depended mainly on between-laboratory differences while within-laboratory differences had only a marginal impact. The results can be used in the development of the standards. (C) 2020 Elsevier Ltd. All rights reserved.
机译:国际标准ISO 3382-2和ISO 3382-3越来越多地应用于确定开放式办公室中的房间声学条件,因为这些工作场所的噪声控制增加了。开放式办事处中这些标准的精确性尚未公布。本研究的目的是确定ISO 3382-2:2008和ISO 3382-3:2012的精度,在开放式办公室之后,在ISO 5725标准的说明之后。此外,涉及与不确定性相关的改进的ISO CD 3382-3:2020的结果分析了结果。安排了精度实验(A.K.A循环试验,实验室测试,互相检验),其中九名独立参与者在同一开放式办公室进行了测量。对于ISO 3382-3:2012,可重复性标准偏差为0.5dB,1.3dB,1.3dB,18%,用于演说的空间衰减率(D-2,DS),距离4米的言语的加权分离( LP,(A,S,4M)),A加权切割背景噪声(LP,LA,LB)和分散距离(R(D))。 ISO Cd 3382-3:2020的相应值分别为0.3dB,1.1dB,0.6 dB和16%。混响时间的再现性标准偏差为125-8000Hz的1/1倍频带内的4.5-16%。 ISO CD 3382-3:2020的测量不确定度小于ISO 3382-3:2012的不确定性。这些值主要取决于实验室之间的差异,而在实验室差异中只有边际效果。结果可用于制定标准。 (c)2020 elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号