A Low-Cost Laboratory-Based Polarimetric Synthetic Aperture Radar System for Scattering Analysis [Education Corner]

机译:用于散射分析的基于实验室的低成本极化合成孔径雷达系统[教育角]

获取原文
获取原文并翻译 | 示例
           

摘要

The scattering mechanisms captured using polarimetric synthetic aperture radar (PolSAR) imaging enable applications like target detection and image classification. This article presents PolSAR images from a unique low-cost, laboratory-based imaging system that captures the basic scattering mechanisms using radar calibration targets, such as a flat plate and dihedral and trihedral corner reflectors. The characterization of the basic scattering mechanisms with good ground truth information is important for classification with PolSAR imagery and for modeling polarimetric signatures. The PolSAR instrument is calibrated using a corner reflector, and the calibration is then validated using an independent data set. The calibration is done in terms of radar cross section (RCS) in decibels referenced to a square meter (dBsm). Results show the system is capable of capturing the basic scattering mechanisms of the single and double bounce. Validation results of the calibration process are off by about 3 dBsm and 4.5 dBsm from the theoretical values of the RCS for the vertical transmit-vertical receive (VV) and horizontal transmit-horizontal receive (HH) channel calibration, respectively. This is acceptable for a low-cost system capable of differentiating scattering mechanisms. This PolSAR system can be used for experimentation within the laboratory for phenomenology studies.
机译:使用极化合成孔径雷达(PolSAR)成像捕获的散射机制使目标检测和图像分类等应用成为可能。本文介绍了来自独特的低成本,基于实验室的成像系统的PolSAR图像,该系统使用雷达校准目标(例如平板,二面和三面角反射器)捕获基本的散射机制。具有良好的地面真实信息的基本散射机制的表征对于用PolSAR影像进行分类和对极化特征进行建模非常重要。使用角反射镜对PolSAR仪器进行校准,然后使用独立的数据集对校准进行验证。校准以参考平方米(dBsm)的分贝为单位的雷达横截面(RCS)进行。结果表明,该系统能够捕获单跳和双跳的基本散射机制。校准过程的验证结果分别相对于垂直发射-垂直接收(VV)和水平发射-水平接收(HH)通道校准的RCS理论值分别降低了约3 dBsm和4.5 dBsm。这对于能够区分散射机制的低成本系统是可以接受的。该PolSAR系统可用于实验室内的现象学研究实验。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号