High energy demand, low cost requirements and higher reliability requirements increase the importance of distributed generation power systems (DGPSs). The large capacity DGPSs requires high performance control algorithms and synchronization techniques based positive-negative sequence (PNS) extractors to fulfil system reliability and power quality requirements under not only during normal operating conditions, but also under unbalanced grid conditions. The power quality problems caused by voltage unbalances, voltage sag/swell, voltage fluctuations, phase faults and harmonic distortions have critical influences on control of power converter devices interfaced DGPSs. In literature studies, novel control strategies with phase locked loops (PLLs) techniques based PNS extractors are used to overcome these problems. In this paper, a comprehensive review on various advanced control strategies and PNS extractors for interlinking three phase inverter in the DGPSs are comprehensively investigated and discussed under normal and abnormal conditions. Several PNS extractors have been overviewed to produce the sequences components required for reference current generation (RCG). The theoretical assessment of the RCG based flexible control strategies and overcurrent limitation control are also comprehensively analysed, surveyed and compared in detail to deal with power quality problems. Comparative analyses for PNS extractors, voltage current regulation controllers and RCG based control strategies have been detailed presented and analysed. The presented detailed overview can be useful to researchers studying impact of normal and abnormal conditions on various control strategies with or without any using PLLs based PNS extractors for three-phase inverters interfaced DGPSs. (C) 2018 Elsevier Ltd. All rights reserved.
机译:高能源需求,低成本要求和更高的可靠性要求提高了分布式发电电源系统(DGPS)的重要性。大容量DGPSS需要高性能控制算法和基于正负序(PNS)提取器的同步技术,以满足在正常操作条件下不仅在正常操作条件下的系统可靠性和功率质量要求,而且在不平衡的网格条件下。由电压不平衡,电压凹槽/膨胀,电压波动,相位故障和谐波扭曲引起的电力质量问题对功率转换器装置的控制具有临界DGPS的控制具有关键影响。在文献研究中,使用基于锁相环(PLL)技术的PNS提取器的新型控制策略来克服这些问题。本文在正常和异常条件下全面研究了对各种先进控制策略和用于相互连接三相逆变器的各种先进控制策略和PNS提取器的全面审查。已经概述了几个PNS提取器以产生参考电流产生所需的序列组分(RCG)。对基于RCG的灵活控制策略和过流限制控制的理论评估也得到了全面分析,调查和比较,详细介绍了能量质量问题。对PNS提取器,电压电流调节控制器和基于RCG的控制策略的比较分析已经详细介绍和分析。本说的详细概述对研究人员对研究正常和异常条件的影响,在使用基于PLLS的PNS提取器对三相逆变器接口DGPS的不同控制策略对各种控制策略的影响。 (c)2018年elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号