The exposure of an 8-year-old child to a femtocell operating at 2600MHz, both (child and source) freely located in random positions in an indoor environment, was assessed. In order to develop surrogate models of the exposure, stochastic dosimetry based on sparse low-rank tensor approximation method (sparse LRA) was used. The surrogate models were used for fastly estimating the specific absorption rate (SAR) in all the possible positions of femtocell and child. Results showed that, for all the possible positions in the room, the exposure values were significantly below the International Commission of Non-Ionizing Radiation Protection (ICNIRP) guidelines for general public and that the probability of reaching SAR values higher than 1% of the ICNIRP guidelines value was lower than 0.006. The variation of the distance between femtocell and child influenced greatly the exposure, resulting in quartile coefficient of dispersion values always higher than 48%.
机译:评估了一个8岁儿童暴露于自由工作在室内环境中随机位置的2600MHz毫微微微小区的辐射。为了建立曝光的替代模型,使用了基于稀疏低秩张量逼近法(稀疏LRA)的随机剂量法。替代模型用于快速估计毫微微小区和儿童所有可能位置的比吸收率(SAR)。结果表明,对于房间中所有可能的位置,其暴露值均大大低于国际非电离辐射防护委员会(ICNIRP)指导原则,并且达到SAR值的可能性高于ICNIRP的1%指导值低于0.006。飞蜂窝与儿童之间的距离变化极大地影响了暴露,导致分散系数值的四分位数系数始终高于48%。