首页> 外文期刊>Annals of Nuclear Medicine >System design and development of a pinhole SPECT system for quantitative functional imaging of small animals
【24h】

System design and development of a pinhole SPECT system for quantitative functional imaging of small animals

机译:用于小动物定量功能成像的针孔SPECT系统的系统设计和开发

获取原文
获取原文并翻译 | 示例
           

摘要

Recently, small animal imaging by pinhole SPECT has been widely investigated by several researchers. We developed a pinhole SPECT system specially designed for small animal imaging. The system consists of a rotation unit for a small animal and a SPECT camera attached with a pinhole collimator. In order to acquire complete data of the projections, the system has two orbits with angles of 90° and 45° with respect to the object. In this system, the position of the SPECT camera is kept fixed, and the animal is rotated in order to avoid misalignment of the center of rotation (COR). We implemented a three dimensional OSEM algorithm for the reconstruction of data acquired by the system from both the orbitals. A point source experiment revealed no significant COR misalignment using the proposed system. Experiments with a line phantom clearly indicated that our system succeeded in minimizing the misalignment of the COR. We performed a study with a rat and99mTc-HMDP, an agent for bone scan, and demonstrated a dramatic improvement in the spatial resolution and uniformity achieved by our system in comparison with the conventional Feldkamp algorithm with one set of orbital data.
机译:近年来,通过针孔SPECT进行的小动物成像已被一些研究人员广泛研究。我们开发了专门用于小型动物成像的针孔SPECT系统。该系统由一个用于小动物的旋转单元和一个装有针孔准直仪的SPECT相机组成。为了获取投影的完整数据,系统具有两个相对于物体成90°角和45°角的轨道。在此系统中,SPECT摄像机的位置保持固定,并且动物旋转以避免旋转中心(COR)发生未对准。我们实现了三维OSEM算法,用于重建系统从两个轨道获取的数据。点源实验表明使用建议的系统没有明显的COR失准。用线幻像进行的实验清楚地表明,我们的系统成功地将COR的未对准降至最低。我们用大鼠和99m Tc-HMDP(一种用于骨扫描的试剂)进行了一项研究,并证明了与一组轨道数据的传统Feldkamp算法相比,我们的系统在空间分辨率和均匀性方面有了显着改善。

著录项

  • 来源
    《Annals of Nuclear Medicine》 |2006年第3期|245-251|共7页
  • 作者单位

    Department of Investigative Radiology National Cardiovascular Center Research Institute 5-7-1 Fujishiro-dai Suita 565-8565 Osaka Japan;

    Department of Investigative Radiology National Cardiovascular Center Research Institute 5-7-1 Fujishiro-dai Suita 565-8565 Osaka Japan;

    Department of Investigative Radiology National Cardiovascular Center Research Institute 5-7-1 Fujishiro-dai Suita 565-8565 Osaka Japan;

    Department of Investigative Radiology National Cardiovascular Center Research Institute 5-7-1 Fujishiro-dai Suita 565-8565 Osaka Japan;

    Department of System Science Graduate School of Informatics Kyoto University Japan;

    Department of Investigative Radiology National Cardiovascular Center Research Institute 5-7-1 Fujishiro-dai Suita 565-8565 Osaka Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    pinhole SPECT; complete data acquisition; small animal imaging;