首页> 外文期刊>Annals of nuclear energy >Technical note Criticality safety of fuel pins in a post irradiation examination cell
【24h】

Technical note Criticality safety of fuel pins in a post irradiation examination cell

机译:技术说明辐照后检查单元中燃料销的临界安全性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper discusses the criticality safety of mixed carbide (70 PuC: 30 UC) fast reactor fuel pins inside the hot cells of a post irradiation examination facility. The criticality calculations are done as a part of the licensing requirements. The present calculations pertain to a situation where 183 fuel pins from three fuel sub-assemblies are inadvertently present at a time in one of the hot cells. In this study, apart from the normal operating condition of the hot cell, two scenarios are considered. One is an accidental situation in which the cell is flooded with water. The other is a hypothetical roof collapse resulting in the fuel pins being embedded in concrete. The calculations are done using Monte Carlo code KENO Va.
机译:本文讨论了辐照后检查设施热室内的混合碳化物(70 PuC:30 UC)快速反应堆燃料销的临界安全性。重要性计算是许可要求的一部分。本计算涉及以下情况:在一个热室之一中,一次偶然地出现了来自三个燃料子组件的183个燃料销。在这项研究中,除了热室的正常运行条件外,还考虑了两种情况。一种是电池被水淹没的偶然情况。另一个是假设的屋顶坍塌,导致燃料针嵌入混凝土中。计算使用蒙特卡罗代码KENO Va完成。