The usual way of testing the equivalence of two measurement procedures is analyzed, and possible alternatives are discussed. It is concluded that for method validation purposes, defining an interval of acceptable values and applying interval hypothesis tests is to be preferred over the usually applied point hypothesis tests. Statistically testing against acceptance limits has the advantage that the beta-error of the usual null hypothesis (there is no bias) can be limited. It is shown that significance testing at a fixed beta-error requires, however, reversal of the usual null and alternative hypotheses. Equations are presented for the case in which the acceptable bias is expressed as a ratio of the reference mean. Moreover, the principle of randomization tests is explained, and their possible advantages over the ordinary test statistics in method validation are discussed.
机译:分析了测试两种测量程序等效性的常用方法,并讨论了可能的替代方法。结论是,出于方法验证的目的,定义可接受值的区间并应用区间假设检验比通常应用的点假设检验更为可取。针对接受极限进行统计检验的优势在于,可以限制常规无效假设(无偏差)的beta误差。结果表明,以固定的beta错误进行显着性检验需要颠倒通常为零和替代的假设。对于将可接受的偏差表示为参考平均值的比率的情况,给出了方程。此外,解释了随机测试的原理,并讨论了它们在方法验证中优于普通测试统计数据的优点。