A renewable-reagent fiber-optic HNO3 sensor was developed for HNO3 measurement in the 0.1-10.0 M range. The HNO3 sensor employs a tubular Nafion cation-exchange membrane to extract acid species from an external HNO3 sample into an internal flowing reagent solution. In high-concentration HNO3 samples, incomplete HNO3 dissociation results in a significant concentration of neutral HNO3 species hi addition to protons. As both neutrals and protons are potentially membrane-permeable species, various reagent compositions were tested to examine the contributions of both acid transfer mechanisms. Continuous reagent flow limited internal acid accumulation rind transferred reagent to the sensor optical detection cell. All reagent compositions included cresol red as a colorimetric indicator, which was measured within the sensor detection cell. Careful fiber-optic alignment provided sufficient light throughput in a back-scatter Illumination mode to allow use of a photodiode array detector for visible spectral acquisition. The use of Ca2+ as a reagent countercation produced notable reductions in HNO3 sensor response to interferent cations and temperature changes. Sensor measurement of HNO3 samples in the tested concentration range produced average relative standard deviations of less than 0.4%, Control over reagent now rate should allow for extension of the HNO3 sensor measurement range to 16.0 M HNO3.
机译:开发了一种可再生试剂光纤HNO3传感器,用于0.1-10.0 M范围内的HNO3测量。 HNO3传感器采用管状的Nafion阳离子交换膜将酸性物质从外部HNO3样品中提取到内部流动的试剂溶液中。在高浓度的HNO3样品中,不完整的HNO3分解导致质子中除了中性HNO3外,还存在大量的中性HNO3。由于中性和质子都可能是可透过膜的物质,因此测试了各种试剂组合物以检验两种酸转移机制的作用。连续的试剂流量限制了内部酸的积累,使果皮将试剂转移至传感器光学检测池。所有试剂组合物均包括甲酚红作为比色指示剂,可在传感器检测池中进行测量。仔细的光纤对准可在反向散射照明模式下提供足够的光通量,以允许使用光电二极管阵列检测器进行可见光谱采集。 Ca2 +作为试剂的抗衡阳离子的使用显着降低了HNO3传感器对干扰阳离子和温度变化的响应。在测试浓度范围内对HNO3样品的传感器测量产生的平均相对标准偏差小于0.4%。控制试剂的现时速率应允许将HNO3传感器的测量范围扩展至16.0 M HNO3。

著录项

  • 来源
    《Analytical Chemistry》 |1996年第17期|p.2890-2896|共7页
  • 作者

    Kuhn KJ; Dyke JT;

  • 作者单位

    Kuhn KJ, LOS ALAMOS NATL LAB, CST-15, LOS ALAMOS, NM 87545, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

    Donnan dialysis; Polymers;

    机译:Donnan透析;聚合物;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号