Automated Needle Trap Heart-Cut GC/MS and Needle Trap Comprehensive Two-Dimensional GC/TOF-MS for Breath Gas Analysis in the Clinical Environment

机译:用于临床环境中呼吸气体分析的自动针阱心脏切割GC / MS和针阱综合二维GC / TOF-MS

获取原文
获取原文并翻译 | 示例
           

摘要

This study was intended to evaluate low-volume (20 mL)nmultibed needle trap (NTD) sampling combined withnheart-cut gas chromatography/mass spectrometry (GCMS) and comprehensive two-dimensional gas chromatographytime-of-flight mass spectrometry (GC × GC/TOFMS)nfor trace gas analysis under clinical conditions. NTDs,nhigh-throughput automatic desorption and separationnsystems, were tested in vitro and within a study in 11npatients undergoing cardiac surgery with respect to reproducibility,nreliability, and clinical applicability. NTDheart-ncut GC/MS analysis of standard mixtures containingndifferent volatile organic compounds (VOCs) yielded relativenstandard deviations (RSDs) from 4.0% to 18.5%.nSubstance adsorption was stable for 1 day if NTDs werenclosed on both ends and was stable for approximatelyn7.8 h when NTD tip ends had to be left open duringnautosampler storage. Even in the presence of high concentrationsnof contaminants linearity of heart-cut GC/MSnwas conserved. In patients’ breath potential biomarkersncould be determined even in the presence of very highnconcentrations of sevoflurane. Profiles of blood-bornenbiomarkers, intravenous drugs, and clinical contaminantsnwere characterized. Comprehensive GC × GC/TOF-MSnmay be used as a screening tool for new biomarkers, ifnpatterns are generated from deconvoluted normalizednareas. Needle trap sampling in combination with hyphenatednchromatographic techniques can thus be used tonprovide well-tailored solutions for complex problemsnoccurring in clinical breath analysis.
机译:这项研究旨在评估低容量(20 mL)n多床针阱(NTD)采样与n切管气相色谱/质谱(GC / nMS)和综合二维气相色谱/ n飞行时间质谱( GC×GC / TOFMS)n用于临床条件下的痕量气体分析。 NTD是高通量自动解吸和分离系统,在11例接受心脏手术的患者的体外,可重复性,可靠性和临床适用性研究中进行了测试。 NTDheart-ncut GC / MS分析包含不同挥发性有机化合物(VOC)的标准混合物的相对标准偏差(RSD)为4.0%至18.5%。n如果两端均封闭NTD,物质吸附稳定1天,并且稳定约7.8。在自动进样器存储过程中NTD尖端必须保持打开状态时。即使存在高浓度的污染物,心切式GC / MSn的线性也得以保留。即使存在非常高浓度的七氟醚,也可以确定患者呼吸中潜在的生物标志物。血液传播的生物标志物,静脉注射药物和临床污染物的特征均已表征。如果从反褶积归一化的尿素中生成n模式,则综合GC×GC / TOF-MSn可用作新生物标记物的筛选工具。因此,可以将针头捕集器与联用色谱法联用,为临床呼吸分析中出现的复杂问题提供量身定制的解决方案。

著录项

  • 来源
    《Analytical Chemistry》 |2010年第6期|p.2541-2551|共11页
  • 作者单位

    Department of Anesthesiology and Intensive Care Medicine, University Rostock, Schillingallee 35, 18057 Rostock,Germany, Institute of Ecological Chemistry, Helmholtz Zentrum Muenchen, Research Center for EnvironmentalHealth, Ingolsta¨ dter Landstrasse 1, 85764 Neuherberg, Germany, PAS Technology Deutschland GmbH,Richard-Wagner-Strasse 10, 99441 Magdala, Germany, and Analytical Chemistry, Institute of Chemistry, UniversityRostock, Albert-Einstein-Strasse 3a 18051 Rostock, Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号