This study aimed at optimizing and validating a sensitive method for simultaneous determination of bisphenol A (BPA), triclosan (TCS), and tetrabromobisphenol A (TBBPA) in human serum using solid-phase extraction (SPE) and gas chromatography coupled to electron-capture negative-ionization mass spectrometry (GC-ECNI/MS). Sample preparation involved denaturation of serum proteins with formic acid followed by SPE on an Oasis HLB cartridge. Fractionation was performed on Florisil from which the phenolic compounds were eluted with methanol-dichloromethane (DCM) (5:1, v/v). The phenolic fraction was further derivatized with pentafluoropropionic acid anhydride (30 min at 70°C). Further liquid-liquid partitioning using hexane-DCM (4:1, v/v) and K2CO3 3% aqueous solution was used to eliminate excess reagent and acidic by-products formed during derivatization. The cleaned extract was injected into a GC-ECNI/MS system operated in selected ion monitoring mode. For thorough method validation, each step of the procedure was rigorously optimized. The method limits of quantitation for BPA, TCS, and TBBPA were 0.28 ng mL?1, 0.09 ng mL?1 and 0.05 ng mL?1, respectively. Furthermore, the method was applied to 21 Belgian human serum samples. The median concentrations obtained for BPA (0.71 ng mL?1) and TCS (0.52 ng mL?1) in Belgian human serum samples were similar to previously reported data for human fluids. Slightly higher levels of TBBPA (0.08 ng mL?1) were found in Belgium samples compared to Norwegian serum.
机译:这项研究旨在优化和验证一种灵敏的方法,该方法使用固相萃取(SPE)和气相色谱-电子捕获技术同时测定人血清中的双酚A(BPA),三氯生(TCS)和四溴双酚A(TBBPA)负离子质谱(GC-ECNI / MS)。样品制备涉及用甲酸使血清蛋白变性,然后在Oasis HLB柱上进行SPE。在Florisil上进行分级分离,用甲醇-二氯甲烷(DCM)(5∶1,v / v)洗脱酚类化合物。酚级分进一步用五氟丙酸酐(在70°C下30分钟)衍生化。使用己烷-DCM(4:1,v / v)和K2 CO3 3%的水溶液进行进一步的液-液分配,以消除衍生过程中形成的过量试剂和酸性副产物。将清洗后的提取物注入以选定离子监测模式运行的GC-ECNI / MS系统。为了进行全面的方法验证,过程的每个步骤均经过严格优化。 BPA,TCS和TBBPA的定量方法限分别为0.28 ng mL?1 ,0.09 ng mL?1 和0.05 ng mL?1 。此外,该方法还应用于21个比利时人血清样品。比利时人血清样品中BPA(0.71 ng mL?1 )和TCS(0.52 ng mL?1 )的中值浓度与先前报道的人体液体数据相似。与挪威血清相比,比利时样品中发现的TBBPA(0.08 ng mL?1 )含量略高。

著录项

  • 来源
    《Analytical and Bioanalytical Chemistry》 |2008年第4期|1175-1181|共7页
  • 作者单位

    Toxicological Centre Department of Pharmaceutical Sciences University of Antwerp Universiteitsplein 1 2610 Wilrijk Belgium;

    Toxicological Centre Department of Pharmaceutical Sciences University of Antwerp Universiteitsplein 1 2610 Wilrijk Belgium;

    Toxicological Centre Department of Pharmaceutical Sciences University of Antwerp Universiteitsplein 1 2610 Wilrijk Belgium;

    Toxicological Centre Department of Pharmaceutical Sciences University of Antwerp Universiteitsplein 1 2610 Wilrijk Belgium;

    Toxicological Centre Department of Pharmaceutical Sciences University of Antwerp Universiteitsplein 1 2610 Wilrijk Belgium;

    Toxicological Centre Department of Pharmaceutical Sciences University of Antwerp Universiteitsplein 1 2610 Wilrijk Belgium;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Bisphenol A; Triclosan; Tetrabromobisphenol A; Solid-phase extraction; Gas chromatography-mass spectrometry; Human serum;

    机译:双酚A三氯生四溴双酚A固相萃取气相色谱-质谱法人血清;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号