首页> 外文期刊>Analytical and Bioanalytical Chemistry >Development of a creatinine enzyme-based bar-code-style lateral-flow assay
【24h】

Development of a creatinine enzyme-based bar-code-style lateral-flow assay

机译:基于肌酸酐酶的条形码式侧流测定法的开发

获取原文
获取原文并翻译 | 示例
           

摘要

A lateral-flow, enzyme-based, bar-code assay for creatinine employing the concept of combination of diffusion and kinetics controlled has been developed. Unlike the traditional bar-code version of immunochromatographic assay, which depends on the stepwise capture of colorimetric tracer-labeled antibody–antigen complex by the immobilized antibody on each successive line, the principle of our proposed assay is based on the delay in TMB release and its diffusion in combination with horseradish peroxidase kinetics. Hydrogen peroxide (H2O2) produced from enzymatic reactions acts as a limiting factor, which controls the rate of conversion of TMB to blue color complex. The assay takes advantage of giving ladder bar result therefore without the need of any reading device. Depending on the amount of enzymes used, the assay can be one (9 min) or two steps (19 min). The strip assay semiquantitatively measures creatinine concentrations ranging from 0 to 400 μM. Thirty urine samples and thirty serum samples were tested, and the assay showed 90.0% and 86.7% agreement compared with conventional Jaffé method, respectively. This assay provides a tool for quick identification of creatinine for patients without the requirement of any instrument.
机译:已经开发出一种采用扩散和动力学控制相结合的概念的肌酐横流,基于酶的条形码测定方法。不同于传统的条形码色谱法的免疫色谱测定法,后者依赖于固定的抗体在每个连续的谱线上逐步捕获比色示踪剂标记的抗体-抗原复合物,我们提出的测定法的原理是基于TMB释放的延迟和它的扩散与辣根过氧化物酶动力学相结合。酶促反应产生的过氧化氢(H2 O2 )是限制因子,它控制TMB转化为蓝色络合物的速率。该测定法利用给出梯形图结果的优势,因此不需要任何读取装置。根据所用酶的量,测定可以是一个步骤(9分钟)或两个步骤(19分钟)。试纸条测定法半定量测定肌酸酐浓度范围为0至400μM。测试了30份尿液样本和30份血清样本,与常规Jaffé方法相比,该测定分别显示90.0%和86.7%的一致性。该测定法提供了无需任何仪器即可快速鉴定患者肌酐的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号