A new immunosensor for the determination of procalcitonin was developed. A sandwich assay format was implemented on a polymethylmetacrylate optical biochip, opportunely shaped in order to obtain several flow channels and potentially suitable for point of care testing applications. The sandwich format makes use of two new rat monoclonal antibodies. The capture antibody was covalently immobilised on the surface of the plastic chip, and the detection antibody was labelled with DY647 dye. Different combinations of capture and detection antibodies were investigated, and particular attention was devoted in order to avoid the non-specific adsorption. A limit of detection of 0.088 mg L?1 was achieved within the working range of 0.28–50 mg L?1 in buffer samples. The assay was also implemented in human serum, and 0.2 and 0.7–25 mg L?1 were the attained limit of detection and working range, respectively.
机译:开发了一种用于测定降钙素的新型免疫传感器。三明治测定法是在聚甲基丙烯酸甲酯光学生物芯片上实施的,其形状合适,以便获得多个流动通道,并可能适用于即时检验应用。三明治格式使用了两种新的大鼠单克隆抗体。将捕获抗体共价固定在塑料芯片的表面,并用DY647染料标记检测抗体。研究了捕获抗体和检测抗体的不同组合,并特别注意以避免非特异性吸附。缓冲液样品在0.28–50 mg L?1 的工作范围内,检出限为0.088 mg L?1 。该测定法也可在人血清中进行,分别达到检测限和工作范围0.2和0.7–25 mg L?1