首页> 外文期刊>Analytical and Bioanalytical Chemistry >A sensitive liquid chromatography–mass spectrometry method for simultaneous determination of alisol A and alisol A 24-acetate from Alisma orientale (Sam.) Juz. in rat plasma
【24h】

A sensitive liquid chromatography–mass spectrometry method for simultaneous determination of alisol A and alisol A 24-acetate from Alisma orientale (Sam.) Juz. in rat plasma

机译:灵敏液相色谱-质谱联用法同时测定东方泽泻(Sam。)Juz的邻苯二酚A和邻苯二酚A 24-乙酸盐。在大鼠血浆中

获取原文
获取原文并翻译 | 示例
       

摘要

A liquid chromatography–mass spectrometry (LC-MS) method was developed and validated for the simultaneous determination of alisol A and alisol A 24-acetate from Alisma orientale (Sam.) Juz. in rat plasma using diazepam as an internal standard. A 200-μl plasma sample was extracted by methyl tert-butyl ether and the separation was performed on Kromasil C18 column (150 × 4.6 mm, 5 μm) with the mobile phase of acetonitrile (containing 0.1% of formic acid)–water (73:27, v/v) at a flow rate of 0.8 ml/min in a run time of 10 min. The two analytes were monitored with positive electrospray ionization by selected ion monitoring mode. The lower limit of quantitation for both alisol A and alisol A 24-acetate were 10 ng/ml. The calibration curves were linear in the measured range 10–1,000 ng/ml for alisol A and 10–500 ng/ml for alisol A 24-acetate. The mean extraction recoveries were above 74.7% for alisol A and above 72.4% for alisol A 24-acetate from biological matrixes. The intra- and inter-day precision for all concentrations of quality controls was lower than 14.1% (RSD %) for each analyte. The accuracy ranged from −12.3% to 9.8% (RE %) for alisol A, and −8.6% to 14.2% (RE %) for alisol A 24-acetate. The method was successfully applied to the study on the pharmacokinetics of alisol A and alisol A 24-acetate in rat plasma.
机译:建立了液相色谱-质谱(LC-MS)方法,并验证了同时测定东方泽泻(Sam。)Juz的邻苯二酚A和邻苯二酚A 24-乙酸盐的有效性。在大鼠血浆中使用地西rat作为内标。用甲基叔丁基醚提取200μl血浆样品,并在Kromasil C 18 色谱柱(150×4.6 mm,5μm)上进行分离,乙腈的流动相为0.1% 10分钟的运行时间内,以0.8毫升/分钟的流速注入甲酸)-水(73:27,v / v)。通过选定的离子监测模式,用正电喷雾电离监测两种分析物。 alisol A和alisol A 24-acetate的定量下限均为10 ng / ml。在10至1,000 ng / ml的测量范围内,对于alisol A而言,校准曲线是线性的;对于alisol A 24-acetate而言,在10–500 ng / ml之间。从生物基质中提取的平均提取回收率对阿索尔A高于74.7%,对阿索尔A 24-乙酸盐高于72.4%。对于每种分析物,所有质量控制浓度的日内和日间精度均低于14.1%(RSD%)。准确度的范围为:阿利索尔A为-12.3%至9.8%(RE%),而阿利索尔24-乙酸盐为-8.6%至14.2%(RE%)。该方法已成功地用于研究大鼠血浆中阿索素A和24-乙酸阿索素A的药代动力学。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号