Enzyme immunoassays with optical detection are amongst the most widely used bioanalytical tools. We defined seven parameters for the quality assessment of immunoassays that were addressed in a systematic study of direct and indirect immunoassays, using the enzymes horseradish peroxidase (HRP) and alkaline phosphatase (AP), the chromogenic substrates 3,3′,5,5′-tetramethylbenzidine (TMB) and para-nitrophenyl phosphate, and the fluorescent substrates 3-(4-hydroxyphenyl)propionic acid and 4-methylumbelliferyl phosphate. The same monoclonal antibody against caffeine was used throughout the study. The four quality parameters regarding the standard curve were the test midpoint (sensitivity), the measurement range, the relative dynamic range of the signal, and the goodness of fit of the adjusted four-parameter logistic function. All HRP immunoassays showed a higher sensitivity compared to the AP assays. On the basis of all four criteria, it was established that the direct assay format is superior to the indirect format, the immunoassay using HRP TMB fulfilling all requirements best. In a second step, caffeine concentrations in 24 beverage and cosmetics samples were determined and three more quality parameters were assessed with this application. The direct HRP TMB assay showed one of the best intra- and inter-plate precisions and the best accuracy, defined by the correlation of results with those from the chosen reference method liquid chromatography tandem mass spectrometry (LC-MS/MS). Considering all criteria, HRP TMB seems to be the enzyme substrate system of choice preferably used in the direct assay format.
机译:具有光学检测功能的酶免疫测定法是使用最广泛的生物分析工具之一。我们使用辣根过氧化物酶(HRP)和碱性磷酸酶(AP)作为生色底物3,3',5,5',定义了七个用于免疫分析质量评估的参数,这些参数已在直接和间接免疫分析的系统研究中解决-四甲基联苯胺(TMB)和对硝基苯基磷酸酯,以及荧光底物3-(4-羟苯基)丙酸和4-甲基伞形磷酸酯。在整个研究中使用了相同的针对咖啡因的单克隆抗体。有关标准曲线的四个质量参数是测试中点(灵敏度),测量范围,信号的相对动态范围以及调整后的四参数逻辑函数的拟合优度。与AP分析相比,所有HRP免疫分析均显示出更高的灵敏度。基于所有四个标准,可以确定直接测定形式优于间接形式,使用HRP TMB的免疫测定最能满足所有要求。第二步,确定24种饮料和化妆品样品中的咖啡因浓度,并通过此应用程序评估另外三个质量参数。直接HRP TMB分析显示出最佳的板内和板间精密度和最佳准确度之一,其精确度由结果与所选参考方法液相色谱串联质谱法(LC-MS / MS)的相关性确定。考虑到所有标准,HRP TMB似乎是优选以直接测定形式使用的酶底物系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号