首页> 外文期刊>American Water Works Association Journal >Performance of Venturi Meters Installed Downstream of Bends
【24h】

Performance of Venturi Meters Installed Downstream of Bends

机译:弯管下游安装的文丘里仪表的性能

获取原文
获取原文并翻译 | 示例
           

摘要

The ability to accurately measure the flow in a closed conduit is essential in today's world in which water conservation is a priority. Current standards specify the recommended upstream straight distances required between fittings such as a 90° elbow and a Venturi flow meter. Although the standards vary for different Venturi flow meters, proper installation is crucial for obtaining an accurate flow measurement. Various tests were performed at the Utah Water Research Laboratory in Logan to determine the effects of a short-form Venturi on the discharge coefficient when the Venturi is installed in piping that does not satisfy the straight length specifications of the current standards. The tests showed that short-form Venturi meters generally perform within the desired accuracy range established by the standards even when placed in piping configurations that do not conform to the requirements set forth in the standards.
机译:在当今世界,节水成为重中之重,准确测量封闭管道中的流量的能力至关重要。当前标准指定了配件(例如90°弯头和文丘里流量计)之间所需的建议上游直线距离。尽管不同的文丘里流量计的标准有所不同,但正确安装对于获得准确的流量测量至关重要。在洛根的犹他州水研究实验室进行了各种测试,以确定当文丘里管安装在不满足当前标准的直管长度规格的管道中时,短形式的文丘里管对排放系数的影响。测试表明,即使放在不符合标准要求的管道配置中,短型文氏管流量计通常也能在标准确定的期望精度范围内发挥作用。