Severity of medication administration errors detected by a bar-code medication administration system

机译:条形码药物管理系统检测到的药物管理错误的严重性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose. The severity of medication administration errors detected by a bar-code medication administration (BCMA) system was studied.rnMethods. A panel of six health care providers reviewed medication administration error scenarios created from BCMA error logs at six community hospitals. Each scenario was rated on the potential to cause patient harm, taking into account the severity of the potential outcome and the probability that the patient would be harmed. A severity score for each error was determined by averaging the individual reviewers'scores. Results. The majority of the medication administration errors identified by the BCMA system were judged to be benign; 1% of the errors reviewed were rated as having the potential to result in a severe or life-threatening adverse event, 8% were judged to have the potential to produce moderate adverse effects, and 91% were expected to produce minimal, if any, clinical effects. Medication errors due to arndose being administered when there was no corresponding order in the computer system were significantly more likely to produce moderate or severe outcomes than other types of medication errors. Errors that involved medications designated as high-alert drugs were also more likely to produce moderate or severe adverse events than non-high-alert drugs. Conclusion. The majority of medication administration errors detected by a BCMA system were judged to be benign and pose minimal safety risks; however, the numbers and severity of medication administration errors that occur despite the use of a BCMA system suggest that there are opportunities to improve these systems and how the information they generate is used.
机译:目的。研究了通过条形码药物管理(BCMA)系统检测到的药物管理错误的严重性。六名医疗保健提供者组成的小组审查了六家社区医院根据BCMA错误日志创建的药物管理错误情况。考虑到潜在后果的严重性和患者受到伤害的可能性,对每种情况下可能造成患者伤害的等级进行了评级。每个错误的严重性评分是通过平均各个评论者的得分来确定的。结果。 BCMA系统识别出的大多数用药错误均被判定为良性;评估的错误中有1%被认为有可能导致严重或危及生命的不良事件,有8%的人被认为有可能产生中度不良反应,而91%的人则被认为可能产生的不良反应极小,临床效果。当计算机系统中没有相应的命令时,由于使用了arndose而导致的药物治疗错误比其他类型的药物治疗错误更有可能产生中等或严重的后果。与非高警戒药物相比,涉及被指定为高警戒药物的错误也更可能产生中度或严重不良事件。结论。 BCMA系统检测到的大多数用药错误均被认为是良性的,并具有最小的安全风险;然而,尽管使用了BCMA系统,但发生的药物管理错误的数量和严重性表明,有机会改进这些系统以及如何使用它们生成的信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号