THE platinum resistance thermometer is the interpolating device for the 1948 International Temperature Scale from ¿182.97 degrees centigrade to +630.5 degrees centigrade.1¿3 When properly made the reproducibility of its resistance justifies its calibration and use for measurements to 0.01 degrees centigrade or 1/80,000th of its temperature range.3 Mueller attacked this difficult resistance-measurement problem with a hand-operated decade bridge.4 Stull attacked the problem with a mechanically balanced recorder using a slide-wire plus decades5 and explained the value of the recorder, one example being the determination of chemical purity by freezing point measurement.6 While Stull was building his recorder the author and his associates were also building a recorder, using one of the several methods of electronic balancing which had then been developed.7, 8 Based on the experience with these two types of recorders there was developed a third type with improved precision, the experimental form of which is the subject of this paper. The commercial form may differ in details from the experimental form described here.
机译:铂电阻温度计是1948年国际温度标度从182.97摄氏度到+630.5摄氏度的内插装置。13正确制作时,其电阻的再现性证明其校准合理,可用于0.01摄氏度或1摄氏度的测量/ 80,000的温度范围。3Mueller用手动十进制电桥解决了这个棘手的电阻测量问题。4Stull通过使用滑线加数十的机械平衡记录仪解决了这个难题,并解释了记录仪的价值,一个例子是通过冰点测量来确定化学纯度。6Stull在建造他的记录仪时,作者和他的同事也在使用后来开发的几种电子平衡方法中的一种来建造记录仪。7,8基于根据这两种类型的记录仪的经验,开发了第三种类型的具有更高精度的记录仪, l本文的主题是表格。商业形式可能与此处所述的实验形式在细节上有所不同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号