首页> 美国卫生研究院文献>Taylor Francis Open Select >Evaluation of dentinal defect formation after root canal preparation with two reciprocating systems and hand instruments: an in vitro study
【2h】

Evaluation of dentinal defect formation after root canal preparation with two reciprocating systems and hand instruments: an in vitro study

机译:用两个往复系统和手动器械评估根管预备后牙本质缺损的形成:一项体外研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this study was to evaluate the presence of dentinal defects after root canal preparation with hand instruments and two different reciprocating instruments. Sixty freshly extracted mandibular incisor teeth were selected for this in vitro study. On the basis of root length, mesiodistal and buccolingual dimensions, the teeth were allocated into three identical experimental groups (n = 15) and one control group (n = 15). The teeth in the control group were left unprepared. The other groups were: stainless steel hand instruments, WaveOne® Primary instruments and RECIPROC® R25 instruments. The reciprocating instruments were used with a reciprocating gentle in-and-out motion in a torque-limited electric motor at the appropriate preset mode. Horizontal sections were made 3, 6 and 9 mm from the apex. Samples were stained with methylene blue and viewed through a stereomicroscope. The presence of dentinal defects (fractures, incomplete cracks and craze lines) and their locations were investigated by two endodontists. These data were analysed statistically by Fisher's exact and chi-square tests. No defects were observed in the unprepared group. All instruments caused dentinal defects, with no significant differences between the instrument systems. All experimental groups demonstrated significantly more defects at the 3-mm level in comparison with the unprepared group (p = 0.032). At the other levels, there was no significant difference between the experimental groups and the control group. The use of hand or reciprocating instruments could induce the formation of dentinal defects during root canal preparation.
机译:这项研究的目的是评估手动器械和两种不同的往复器械在根管预备后牙本质缺损的存在。选择了60颗新鲜提取的下颌切牙用于该体外研究。根据牙根长度,近中颌角和颊舌尺寸,将牙齿分为三个相同的实验组(n = 15)和一个对照组(n = 15)。对照组的牙齿没有准备好。其他组是:不锈钢手动仪器,WaveOne®Primary仪器和RECIPROC®R25仪器。在适当的预设模式下,往复式器械在扭矩受限的电动机中以缓慢的往复运动来使用。距顶部3、6和9 mm处形成水平截面。样品用亚甲蓝染色并通过立体显微镜观察。两名牙髓医生调查了牙本质缺陷(骨折,不完整的裂纹和裂纹线)的存在及其位置。通过Fisher精确和卡方检验对这些数据进行统计分析。在未准备的组中未观察到缺陷。所有器械均引起牙齿缺陷,器械系统之间无明显差异。与未准备的组相比,所有实验组在3mm的水平上均表现出明显更多的缺陷(p = 0.032)。在其他水平上,实验组和对照组之间没有显着差异。在根管准备过程中,使用手动或往复式器械可能会导致牙本质缺损的形成。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号