首页> 美国卫生研究院文献>Springer Open Choice >The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron
【2h】

The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron

机译:四种快速中子活体内检测硼的中子源进行快速伽玛中子活化分析(PGNAA)的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A Prompt Gamma Ray Neutron Activation Analysis (PGNAA) system, incorporating an isotopic neutron source has been simulated using the MCNPX Monte Carlo code. In order to improve the signal to noise ratio different collimators and a filter were placed between the neutron source and the object. The effect of the positioning of the neutron beam and the detector relative to the object has been studied. In this work the optimisation procedure is demonstrated for boron. Monte Carlo calculations were carried out to compare the performance of the proposed PGNAA system using four different neutron sources (241Am/Be, 252Cf, 241Am/B, and DT neutron generator). Among the different systems the 252Cf neutron based PGNAA system has the best performance.
机译:使用MCNPX蒙特卡洛代码对包含同位素中子源的瞬发伽马射线中子活化分析(PGNAA)系统进行了模拟。为了提高信噪比,在中子源和物体之间放置了不同的准直器和滤波器。已经研究了中子束和探测器相对于物体的定位效果。在这项工作中,对硼的优化程序进行了演示。进行了蒙特卡洛计算,以比较使用四种不同中子源( 241 Am / Be, 252 Cf, 241 Am / B和DT中子发生器)。在不同的系统中,基于 252 Cf中子的PGNAA系统具有最佳性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号