Eight elastomeric composites (NRU, GR1–GR4, NRBG08–NRBG24) containing mixtures of different proportions of heavy metal additives (Bi, W, Gd and Sb) have been synthesized and examined as protective shields. The NRU sample was a pure rubber matrix and served as a reference sample for heavy metal modified composites. Experimental procedure used for evaluation of the composite shields and their attenuation properties was based on the utilization of HPGe spectrometry and analysis of X-ray fluorescence radiation intensity of the heavy metal additives in the following energy ranges for: Sb (20–35 keV), Gd (35–55 keV), W (55–70 keV) and Bi (70–90 keV). The main contributor to the induced X-ray fluorescence radiation within the shield is Bi additive and the intensity of the X-ray radiation generated within the energy range of 70–90 keV strongly depends on its concentration. It was found that decreasing concentration of the Bi fraction from 0.35 (GR samples) to 0.15 (NRBG samples) results in significant lowering Bi X-ray fluorescence radiation within the 70–90 keV energy range. Secondary effect of decreasing Bi concentration was efficient diminishing excitation processes for lower Z heavy metal additives (W, Gd and Sb, GR vs. NRBG samples). As the final quality parameter of the shielding properties for the examined elastomers, dose reduction factor (DRF) coefficients were calculated for each shield. It was found, that the best shielding properties are observed for composites with lower Bi concentration (0.15 vs. 0.35 Bi mass fraction) with only slight further improvement of their parameters (DRF) with increasing of Gd concentration (Gd mass fraction 0.08, 0.16 and 0.24). The most efficient dose reduction composite was found to be NRBG24 elastomer with DRF value 0.47 (53 % dose reduction) for ca. 2 mm and 0.44 g/cm2 layer thickness.
机译:合成了八种弹性体复合材料(NRU,GR1-GR4,NRBG08-NRBG24),其中包含不同比例的重金属添加剂(Bi,W,Gd和Sb)的混合物,并用作防护罩。 NRU样品是纯橡胶基质,可作为重金属改性复合材料的参考样品。用于评估复合屏蔽及其衰减特性的实验程序是基于HPGe光谱的利用和以下能量范围内重金属添加剂的X射线荧光辐射强度分析:Sb(20-35keV), Gd(35-55keV),W(55-70keV)和Bi(70-90keV)。屏蔽层内引起的X射线荧光辐射的主要贡献是Bi添加剂,并且在70-90keV能量范围内产生的X射线辐射的强度很大程度上取决于其浓度。已发现将Bi分数的浓度从0.35(GR样品)降低到0.15(NRBG样品)会导致在70-90keV能量范围内显着降低Bi X射线荧光辐射。降低Bi浓度的次要效果是有效降低了Z含量较低的重金属添加剂(W,Gd和Sb,GR与NRBG样品)的激发过程。作为所检查的弹性体的屏蔽性能的最终质量参数,为每个屏蔽计算了剂量减少因子(DRF)系数。已发现,对于Bi浓度较低的复合材料(Bi质量分数为0.15与0.35 Bi),观察到最佳的屏蔽性能,但随着Gd浓度的增加(Gd质量分数为0.08、0.16和0.5),其参数(DRF)仅有少许进一步改善。 0.24)。发现最有效的降低剂量的复合材料是NRBG24弹性体,其DRF值约为0.47(剂量减少53%)。 2毫米和0.44 g / cm 2 层厚度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号