首页> 美国卫生研究院文献>Springer Open Choice >Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol
【2h】

Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol

机译:简单的减量协议实施后在三维旋转血管造影中大幅降低剂量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Previously, median effective dose (ED) of 1.6 mSv per three-dimensional rotational angiography (3DRA) has been reported. This study evaluated ED and image quality in 3DRA after implementation of a simple dose reduction protocol in pediatric catheterizations. Simple conversion factors between 3DRA ED and readily available parameters at the cathlab were determined. The dose reduction protocol consisted of frame reduction (60–30 frames/s (f/s)), active collimation of the X-ray beam, usage of a readily available low dosage program, and a pre-3DRA run check. EDs were calculated with Monte Carlo PCXMC 2.0. Three observers blindly assessed 3DRA image quality of the dose reduction and normal-dose cohort. Between October 2014 and October 2015, 84 patients (median age 4.3 years) underwent 100 3DRAs with a median ED of 0.54 mSv (0.12–2.2) using the dose reduction protocol. Median ED in the normal-dose cohort (17 3DRAs) was 1.6 mSv (1.2–4.9). Image quality in the dose reduction cohort remained excellent. Correlations between ED and dose area product (DAP) and ED and skin dose were found with a ρ of 0.82 and 0.83, respectively. ED exposure of the entire catheterization was reduced to 2.64 mSv. Introduction of a simple protocol led to 66% dose reduction in 3DRA and 79% in the entire catheterization. 3DRA image quality in this group remained excellent. In 3DRA ED correlates well with DAP and skin dose, parameters readily available at the cathlab.Electronic supplementary materialThe online version of this article (10.1007/s00246-018-1943-3) contains supplementary material, which is available to authorized users.
机译:以前,据报道每三维旋转血管造影(3DRA)的中位有效剂量(ED)为1.6 mSv。这项研究在小儿导管插入术中实施了简单的剂量减少方案后,评估了3DRA中的ED和图像质量。确定了3DRA ED和Cathlab上容易获得的参数之间的简单转换因子。剂量减少方案包括减少帧数(60–30帧/秒(f / s)),主动准直X射线束,使用现成的低剂量程序以及3DRA之前的运行检查。用Monte Carlo PCXMC 2.0计算ED。三名观察员盲目评估了剂量减少和正常剂量队列的3DRA图像质量。在2014年10月至2015年10月之间,使用减量方案对84例患者(中位年龄为4.3岁)进行了100次3DRA,ED中位数为0.54 mSv(0.12-2.2)。正常剂量队列中的ED中位数(17 3DRA)为1.6 mSv(1.2–4.9)。降低剂量组的图像质量保持出色。发现ED与剂量面积积(DAP)之间的相关性以及ED与皮肤剂量之间的相关性,其ρ分别为0.82和0.83。整个导管插入术的ED暴露降低至2.64 mSv。引入一个简单的方案导致3DRA剂量减少66%,整个导管插入减少79%。该组的3DRA图像质量保持出色。在3DRA中,ED与DAP和皮肤剂量密切相关,参数可在cathlab上获得。电子补充材料本文的在线版本(10.1007 / s00246-018-1943-3)包含补充材料,授权用户可以使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号