Previously, median effective dose (ED) of 1.6?mSv per three-dimensional rotational angiography (3DRA) has been reported. This study evaluated ED and image quality in 3DRA after implementation of a simple dose reduction protocol in pediatric catheterizations. Simple conversion factors between 3DRA ED and readily available parameters at the cathlab were determined. The dose reduction protocol consisted of frame reduction (60–30 frames/s (f/s)), active collimation of the X-ray beam, usage of a readily available low dosage program, and a pre-3DRA run check. EDs were calculated with Monte Carlo PCXMC 2.0. Three observers blindly assessed 3DRA image quality of the dose reduction and normal-dose cohort. Between October 2014 and October 2015, 84 patients (median age 4.3?years) underwent 100 3DRAs with a median ED of 0.54?mSv (0.12–2.2) using the dose reduction protocol. Median ED in the normal-dose cohort (17 3DRAs) was 1.6?mSv (1.2–4.9). Image quality in the dose reduction cohort remained excellent. Correlations between ED and dose area product (DAP) and ED and skin dose were found with a ρ of 0.82 and 0.83, respectively. ED exposure of the entire catheterization was reduced to 2.64?mSv. Introduction of a simple protocol led to 66% dose reduction in 3DRA and 79% in the entire catheterization. 3DRA image quality in this group remained excellent. In 3DRA ED correlates well with DAP and skin dose, parameters readily available at the cathlab.
机译:以前,已经报道了每三维旋转血管造影(3DRA)的1.6□MSV的中值有效剂量(ED)。该研究在小儿导管引出的简单剂量降低方案实施后,在3DRA中评估了ED和图像质量。确定了Cathlab的3DRA ED和易于可用参数之间的简单转换因子。减少剂量减少协议由帧减少(60-30帧/秒(f / s)),X射线束的主动准直,易于使用的低剂量程序和3DRA预先运行检查。使用Monte Carlo PCXMC 2.0计算EDS。三个观察者盲目地评估了剂量减少和正常剂量队列的3DRA图像质量。 2014年10月至2015年10月期间,84名患者(中位数4.3岁?年)介绍了100个3dras,中位数为0.54Ω·msv(0.12-2.2),使用剂量减少方案。正常剂量队列(17 3dras)中的中位数为1.6?MSV(1.2-4.9)。剂量减少队列中的图像质量仍然优异。 ED和剂量区域产品(DAP)和ED和皮肤剂量的相关性分别发现0.82和0.83的ρ。 ED整个导尿曝光减少到2.64?MSV。简单方案的引入导致3DRA的66%降低,在整个导管中减少79%。 3DRA在这个组中的图像质量仍然很好。在3DRA中,用DAP和皮肤剂量良好地关联,Cathlab在Cathlab上容易获得的参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号