Whole-body dual-energy X-ray absorptiometry demonstrates better reliability than segmental body composition analysis in college-aged students

机译:全身双能X线骨密度仪显示出比分段身体成分分析更好的可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Dual-energy X-ray absorptiometry (DXA) is rapidly becoming more accessible and popular as a technique to monitor body composition. The reliability of DXA has been examined extensively using a number of different methodological approaches. This study sets up to investigate the accuracy of measuring the parameters of body composition (BC) by means of the whole-body and the segmental DXA method analysis with the typical error of measurement (TEM) that allows for expressing the error in the units of measure. The research was implemented in a group of 63 participants, all of whom were university students. Thirty-eight males (22.6±2.9 years, average body mass 77.5±8.4 kg) and 25 females (21.4±2.0 years, average body mass 58.6±7.2 kg) were recruited. The measured parameters included body mass (BM), fat-free mass (FFM), body fat (BF), bone mineral content (BMC), bone mineral density (BMD). For the whole-body analysis, the determined TEM was: BM at the level of 0.12 kg in females and 0.29 kg in males; BF 0.25kg and 0.44% females, 0.52 kg and 0.66% males; FFM 0.24 kg females and 0.42 kg males; BMC 0.02 kg females and males; BMD 0.01g/cm2 females and males. The TEM values in the segmental analysis were: BF within the range of 0.04–0.28 kg and 0.68–1.20% in females, 0.10–0.36 kg and 0.72–1.94% in males; FFM 0.08–0.41 kg females and 0.17–0.86 males, BMC 0.00–0.02 kg females and 0.01–0.02 kg males in relation to the body segment (upper limb, trunk, lower limb). The BMD value was at the level of 0.01–0.02g/cm2. The study results showed high reliability in measuring body composition parameters using the DXA method. The whole-body analysis showed a higher accuracy of measurement than the segmental. Only the changes that are greater than the TEM, or the upper bound (95%) of the confidence interval of the measurement can be considered demonstrable when interpreting repeated measurements.
机译:双能X射线吸收法(DXA)作为监测人体成分的技术正迅速变得越来越普及。 DXA的可靠性已使用多种不同的方法论进行了广泛的检查。本研究旨在研究通过全身和分段DXA方法分析测量身体成分(BC)参数的准确性,并采用典型的测量误差(TEM)来表示误差的单位为测量。这项研究由63名参与者组成,他们都是大学生。招募了38名男性(22.6±2.9岁,平均体重77.5±8.4 kg)和25名女性(21.4±2.0岁,平均体重58.6±7.2 kg)。测得的参数包括体重(BM),无脂肪质量(FFM),体脂(BF),骨矿物质含量(BMC),骨矿物质密度(BMD)。对于全身分析,确定的TEM为:雌性BM为0.12 kg,雄性为BM 0.29 kg。高炉0.25公斤和0.44%的雌性,0.52公斤和0.66%的雄性;实况调查团雌性0.24公斤,雄性0.42公斤;雌性和雄性BMC 0.02公斤;雌性和雄性BMD 0.01g / cm 2 。分段分析的TEM值是:女性的高炉在0.04-0.28 kg和0.68-1.20%之间,男性在0.10-0.36 kg和0.72-1.94%之间;相对于身体部位(上肢,躯干,下肢)而言,女性FFM为0.08–0.41 kg,男性为0.17–0.86,BMC为0.00–0.02 kg,女性为0.01–0.02 kg。 BMD值在0.01-0.02g / cm 2 的水平。研究结果表明,使用DXA方法测量身体成分参数具有很高的可靠性。全身分析显示出比分段测量更高的测量精度。在解释重复的测量值时,只有大于TEM的变化或测量值的置信区间的上限(95%)才被认为是可证明的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号