Minimising Mortality in Endangered Raptors Due to Power Lines: The Importance of Spatial Aggregation to Optimize the Application of Mitigation Measures

机译:最大限度地降低因电源线造成的危险猛禽的死亡率:优化空间聚集措施对缓解措施的应用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Electrocution by power lines is one of the main causes of non-natural mortality in birds of prey. In an area in central Spain, we surveyed 6304 pylons from 333 power lines to determine electrocution rates, environmental and design factors that may influence electrocution and the efficacy of mitigation measures used to minimise electrocution cases. A total of 952 electrocuted raptors, representing 14 different species, were observed. Electrocuted raptors were concentrated in certain areas and the environmental factors associated with increased electrocution events were: greater numbers of prey animals; greater vegetation cover; and shorter distance to roads. The structural elements associated with electrocutions were shorter strings of insulators, one or more phases over the crossarm, cross-shaped design and pylon function. Of the 952 carcasses found, 148 were eagles, including golden eagle (Aquila chrysaetos), Spanish imperial eagle (Aquila adalberti) and Bonelli's eagle (Aquila fasciata). Electrocuted eagles were clustered in smaller areas than other electrocuted raptors. The factors associated with increased eagle electrocution events were: pylons function, shorter strings of insulators, higher slopes surrounding the pylon, and more numerous potential prey animals. Pylons with increased string of insulators had lower raptor electrocution rates than unimproved pylons, although this technique was unsuccessful for eagles. Pylons with cable insulation showed higher electrocution rates than unimproved pylons, both for raptors and eagles, despite this is the most widely used and recommended mitigation measure in several countries. To optimize the application of mitigation measures, our results recommend the substitution of pin-type insulators to suspended ones and elongating the strings of insulators.
机译:电力线电死是猛禽非自然死亡的主要原因之一。在西班牙中部一个地区,我们对333条电力线的6304个塔进行了调查,以确定电死率,可能影响电死的环境因素和设计因素以及用于最大程度减少电死案例的缓解措施的有效性。共观察到代表14种不同物种的952个电击猛禽。电击猛禽集中在某些地区,与电击事件增加有关的环境因素是:猎物数量增加;更大的植被覆盖;到公路的距离更短。与触电致死有关的结构要素是较短的绝缘子串,横臂上的一个或多个相,十字形设计和铁塔功能。在发现的952具尸体中,有148具是鹰,包括金鹰(Aquila chrysaetos),西班牙帝国鹰(Aquila adalberti)和Bonelli的鹰(Aquila fasciata)。与其他电死猛禽相比,电死鹰聚集在较小的区域。与老鹰电击事件增加相关的因素是:塔架功能,绝缘子串更短,塔架周围的坡度更高以及更多的潜在猎物。尽管这种技术对老鹰而言并不成功,但具有增加的绝缘子串的定向塔的猛禽电击穿率要低于未经改进的定向塔。尽管是几个国家中使用最广泛且推荐的缓解措施,但电缆绝缘的定向塔对猛禽和老鹰的电死率均高于未经改进的定向塔。为了优化缓解措施的应用,我们的结果建议将引脚型绝缘子替换为悬挂式绝缘子,并延长绝缘子的串。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号