Thermography Applied During Exercises With or Without Infrared Light-Emitting Diode Irradiation: Individual and Comparative Analysis

机译:在有或没有红外发光二极管照射的运动过程中使用的热成像:个体和比较分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Objective: The aim of our study was to evaluate the cutaneous temperature during an exercise on a treadmill with or without infrared light-emitting diode (LED) irradiation in postmenopausal women. >Background data: Thermography is an imaging technique in which radiation emitted by a body in the middle and far infrared spectrum is detected and associated with the temperature of the body's surface. >Materials and methods: Eighteen postmenopausal women were randomly divided into two groups: (1) the LED group, which performed the exercises on a treadmill associated with phototherapy (n=9) and; (2) the exercise group, which performed the exercises on a treadmill without additional phototherapy (n=9). The irradiation parameters for each women's thigh were: array of 2000 infrared LEDs (850 nm) with an area of 1,110 cm2, 100 mW, 39 mW/cm2, and 108 J/cm2 for 45 min. The submaximal constant-speed exercise on the treadmill at intensities between 85% and 90% maximal heart rate (HRmax) with or without phototherapy were performed during 45 min, to perform the thermographic analysis. Thermography images were captured before the exercise (t=0), after 10, 35, and 45 min of exercising (t=10, t=35, and t=45) and at 5 min post-exercising (t=50). >Results>: The LED group showed an increased cutaneous thigh temperature during the exercise (from 33.5±0.8°C to 34.6±0.9°C, p=0.03), whereas the exercise group showed a reduced cutaneous temperature (from 33.5±0.6 to 32.7±0.7°C, p=0.02). The difference between the groups was significant (p<0.05) at t=35, t=45, and t=50. >Conclusions: These data indicate an improved microcirculation, and can explain one possible mechanism of action of phototherapy associated with physical exercises.
机译:>目的:我们的研究目的是评估绝经后妇女在有或没有红外发光二极管(LED)照射的跑步机上运动时的皮肤温度。 >背景数据:热成像技术是一种成像技术,可检测人体在中红外光谱和远红外光谱中发出的辐射并将其与身体表面温度相关联。 >材料和方法:将18名绝经后妇女随机分为两组:(1)LED组,该组在与光疗相关的跑步机上进行锻炼(n = 9);以及(2)运动组,该运动组在跑步机上进行锻炼而无需额外的光疗(n = 9)。每个女性大腿的照射参数为:2000个红外LED阵列(850 nm),面积分别为1,110 cm 2 ,100 mW,39 mW / cm 2 和108 J / cm 2 持续45 min。在45分钟内,在有或没有光疗的情况下,在跑步机上以85%至90%最大心率(HRmax)的强度进行次最大恒速运动,以进行热成像分析。在运动前(t = 0),运动后10、35和45分钟(t = 10,t = 35和t = 45)以及运动后5分钟(t = 50)捕获热成像图像。 >结果 >:在运动过程中,LED组的皮肤大腿温度升高(从33.5±0.8°C到34.6±0.9°C,p = 0.03)。组表现出降低的皮肤温度(从33.5±0.6降至3​​2.7±0.7°C,p = 0.02)。两组之间的差异在t = 35,t = 45和t = 50时显着(p <0.05)。 >结论:这些数据表明微循环得到改善,并可以解释与体育锻炼有关的光疗作用的一种可能机制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号