pneuRIPTM: A Novel Respiratory Inductance Plethysmography Monitor

机译:pneuRIPTM:新型的呼吸感应心律描记仪

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective pulmonary function (PF) evaluation is essential for the diagnosis, monitoring, and management of many pediatric respiratory diseases as seen in the emergency room, intensive care, and outpatient settings. In this paper, the development and testing of a new noninvasive PF instrument, pneuRIPTM, which utilizes respiratory inductance plethysmography (RIP) are discussed. The pneuRIPTM hardware includes a small circuit board that connects to the RIP bands and measures and wirelessly transmits the band inductance data to any designated wirelessly connected tablet. The software provides indices of respiratory work presented instantaneously in a user-friendly graphical user interface on the tablet. The system was tested with ten normal children and compared with an existing system, Respitrace (Sensormedics, Yorba Linda, CA), under normal and loaded breathing conditions. Under normal breathing, the percentage differences between the two systems were 2.9% for labored breathing index (LBI), 31.8% for phase angle (Φ), 4.8% for percentage rib cage (RC%), and 26.7% for respiratory rate (BPM). Under loaded breathing, the percentage differences between the two systems were 1.6% for LBI, 4.1% for Φ, 8.5% for RC%, and 52.7% for BPM. For LBI, Φ, and RC%, the two systems were in general agreement. For BPM the pneuRIPTM is shown to be more accurate than the respitrace when compared to manually counting the breaths: 13.2% versus 36.4% accuracy for normal breathing and 16.9% versus 60.7% accuracy for breathing under load, respectively.
机译:在急诊室,重症监护室和门诊患者中,客观的肺功能(PF)评估对于许多儿科呼吸系统疾病的诊断,监测和管理至关重要。本文讨论了利用呼吸电感体积描记法(RIP)的新型无创PF仪器pneuRIP TM 的开发和测试。 pneuRIP TM 硬件包括一块小型电路板,该电路板连接到RIP频段并进行测量,并将频段电感数据无线传输到任何指定的无线连接平板电脑。该软件可在平板电脑上的用户友好图形用户界面中即时显示呼吸功指标。该系统在正常和负重呼吸条件下对十名正常儿童进行了测试,并与现有系统Respitrace(Sensormedics,Yorba Linda,CA)进行了比较。在正常呼吸下,两个系统之间的呼吸呼吸指数(LBI)的百分比差异为2.9%,相角(Φ)的31.8%,肋骨百分比(RC%)的4.8%和呼吸频率(BPM)的26.7% )。在负重呼吸下,两个系统之间的百分比差异对于LBI为1.6%,对于Φ为4.1%,对于RC%为8.5%,对于BPM为52.7%。对于LBI,Φ和RC%,两个系统基本一致。对于BPM,与手动计数呼吸相比,pneuRIP TM 显示出的精度要高于respitrace:正常呼吸的准确度为13.2%比36.4%,负荷下呼吸的准确度为16.9%比60.7%,分别。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号