The present work describes the design of a device/system intended to induce local mild hypothermia by simultaneously cooling a patient's head and neck. The therapeutic goal is to lower the head and neck temperatures to 33–35 °C, while leaving the core body temperature unchanged. The device works by circulating a cold fluid around the exterior of the head and neck. The head surface area is separated into five different cooling zones. Each zone has a cooling coil and can be independently controlled. The cooling coils are tightly wrapped concentric circles of tubing. This design allows for a dense packing of tubes in a limited space, while preventing crimping of the tubing and minimizing the fluid pressure head loss. The design in the neck region also has multiple tubes wrapping around the circumference of the patient's neck in a helix. Preliminary testing indicates that this approach is capable of achieving the design goal of cooling the brain tissue (at a depth of 2.5 cm from the scalp) to 35 °C within 30– 40 min, without any pharmacologic or circulatory manipulation. In a comparison with examples of current technology, the device has shown the potential for improved cooling capability.
机译:本工作描述了旨在通过同时冷却患者的头部和颈部来引起局部轻度低温的设备/系统的设计。治疗的目标是将头和颈部的温度降低到33–35 C,同时保持核心体温不变。该设备通过使冷流体在头部和颈部外部周围循环来工作。头部表面区域分为五个不同的冷却区域。每个区域都有一个冷却盘管,可以独立控制。冷却盘管紧紧缠绕在同心圆管上。这种设计允许在有限的空间内密集地填充管子,同时防止管子卷曲,并最大程度地减少流体压力头损失。颈部区域的设计还具有多根螺旋形缠绕在患者颈部周围的管子。初步测试表明,这种方法能够实现在30至40分钟内将脑组织(距头皮2.5厘米深处)冷却至35摄氏度的设计目标,而无需任何药理或循环操作。与当前技术的示例进行比较,该设备显示了改进冷却能力的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号