  • 机译 罕见疾病的儿童和成人需要创新的医疗设备
    摘要:Rare diseases (RD) affect approximately 30 million Americans, half of whom are children. This study is the first to comprehensively evaluate their medical device needs via a survey of physicians. The study sought to identify and document the presumed unmet diagnostic and therapeutic device needs for RD management; clarify the magnitude of the potential unmet need; and generate meaningful data to inform medical device stakeholders. A cross-sectional nonprobability survey was conducted. The study population was drawn from the membership files of four groups: FDA Medical Devices Advisory Committee, Pediatric Advisory Committee, Pediatric Device Consortia, and National Institutes of Health (NIH) Rare Diseases Clinical Research Network. Only physician respondents with experience or knowledge regarding RD were eligible. Among eligible respondents, 90% confirmed the need for innovative devices to care for people with RD. Over 850 device needs were identified for 436 RD, with 74% of needs related to children. Pediatric physicians (OR = 2.11, 95% CI 1.01–4.39, P = 0.046) and physicians with more RD experience reflected greater dissatisfaction with existing devices (OR = 4.49, 95% CI 2.25–8.96, P < 0.0001). Creation of entirely new devices is the top recommendation for mitigating needs. This study demonstrates a major public health need for innovative medical devices to care for children and adults with RD. FDA and NIH support and seek opportunities to accelerate device development for these vulnerable patients.
  • 机译 重叠支架植入过程的有限元分析
    摘要:Overlapping stents are widely used in vascular stent surgeries. However, the rate of stent fractures (SF) and in-stent restenosis (ISR) after using overlapping stents is higher than that of single stent implantations. Published studies investigating the nature of overlapping stents rely primarily on medical images, which can only reveal the effect of the surgery without providing insights into how stent overlap influences the implantation process. In this paper, a finite element analysis of the overlapping stent implantation process was performed to study the interaction between overlapping stents. Four different cases, based on three typical stent overlap modes and two classical balloons, were investigated. The results showed that overlapping contact patterns among struts were edge-to-edge, edge-to-surface, and noncontact. These were mainly induced by the nonuniform deformation of the stent in the radial direction and stent tubular structures. Meanwhile, the results also revealed that the contact pressure was concentrated in the edge of overlapping struts. During the stent overlap process, the contact pattern was primarily edge-to-edge contact at the beginning and edge-to-surface contact as the contact pressure increased. The interactions between overlapping stents suggest that the failure of overlapping stents frequently occurs along stent edges, which agrees with the previous experimental research regarding the safety of overlapping stents. This paper also provides a fundamental understanding of the mechanical properties of overlapping stents.
  • 机译 计算建模和仿真在外围血管设备总产品生命周期中的作用
    摘要:The total product life cycle (TPLC) of medical devices has been defined by four stages: discovery and ideation, regulatory decision, product launch, and postmarket monitoring. Manufacturers of medical devices intended for use in the peripheral vasculature, such as stents, inferior vena cava (IVC) filters, and stent-grafts, mainly use computational modeling and simulation (CM&S) to aid device development and design optimization, supplement bench testing for regulatory decisions, and assess postmarket changes or failures. For example, computational solid mechanics and fluid dynamics enable the investigation of design limitations in the ideation stage. To supplement bench data in regulatory submissions, manufactures can evaluate the effects of anatomical characteristics and expected in vivo loading environment on device performance. Manufacturers might also harness CM&S to aid root-cause analyses that are necessary when failures occur postmarket, when the device is exposed to broad clinical use. Once identified, CM&S tools can then be used for redesign to address the failure mode and re-establish the performance profile with the appropriate models. The Center for Devices and Radiological Health (CDRH) wants to advance the use of CM&S for medical devices and supports the development of virtual physiological patients, clinical trial simulations, and personalized medicine. Thus, the purpose of this paper is to describe specific examples of how CM&S is currently used to support regulatory submissions at different phases of the TPLC and to present some of the stakeholder-led initiatives for advancing CM&S for regulatory decision-making.
  • 机译 针头尺寸的手术器械的设计制造和测试
    摘要:This paper presents a miniature wrist that can be integrated into needle-sized surgical instruments. The wrist consists of a nitinol tube with asymmetric cutouts that is actuated by a single tendon to provide high distal curvature. We derive and experimentally validate kinematic and static models for the wrist and describe several prototype wrists, illustrating the straightforward fabrication and scalability of the design. We experimentally investigate fatigue life, the concept of tip-first bending, and practical use of the wrist with a concentric tube robot in an endonasal surgical scenario.
  • 机译 设计负担得起的有线导航手术模拟器
    摘要:
  • 机译 为膝上假体提供真空辅助悬架的原型混合真空泵的评估
    摘要:Vacuum-assisted suspension (VAS) of prosthetic sockets utilizes a pump to evacuate air from between the prosthetic liner and socket, and are available as mechanical or electric systems. This technical note describes a hybrid pump that benefits from the advantages of mechanical and electric systems, and evaluates a prototype as proof-of-concept. Cyclical bench testing of the hybrid pump mechanical system was performed using a materials testing system to assess the relationship between compression cycles and vacuum pressure. Phase 1 in vivo testing of the hybrid pump was performed by an able-bodied individual using prosthesis simulator boots walking on a treadmill, and phase 2 involved an above-knee prosthesis user walking with the hybrid pump and a commercial electric pump for comparison. Bench testing of 300 compression cycles produced a maximum vacuum of 24 in-Hg. In vivo testing demonstrated that the hybrid pump continued to pull vacuum during walking, and as opposed to the commercial electric pump, did not require reactivation of the electric system during phase 2 testing. The novelty of the hybrid pump is that while the electric system provides rapid, initial vacuum suspension, the mechanical system provides continuous air evacuation while walking to maintain suspension without reactivation of the electric system, thereby allowing battery power to be reserved for monitoring vacuum levels.
  • 机译 补偿技术用于软组织表征的生物阻抗谱仪的设计
    摘要:Bioimpedance spectroscopy (BIS) has shown significant potential in many areas of medicine to provide new physiologic markers. Several acute and chronic diseases are accompanied by changes in intra- and extracellular fluid within various areas of the human body. The estimation of fluid in various body compartments is therefore a simple and convenient method to monitor certain disease states. In this work, the design and evaluation of a BIS instrument are presented and three key areas of the development process investigated facilitating the BIS measurement of tissue hydration state. First, the benefit of incorporating DC-stabilizing circuitry to the standard modified Howland current pump (MHCP) is investigated to minimize the effect of DC offsets limiting the dynamic range of the system. Second, the influence of the distance between the bioimpedance probe and a high impedance material is investigated using finite element analysis (FEA). Third, an analytic compensation technique is presented to minimize the influence of parasitic capacitance. Finally, the overall experimental setup is evaluated through ex vivo BIS measurements of porcine spleen tissue and compared to published results. The DC-stabilizing circuit demonstrated its ability to maintain DC offsets at less than 650 μV through 100 kHz while maintaining an output impedance of 1 MΩ from 100 Hz to 100 kHz. The proximity of a bioimpedance probe to a high impedance material such as acrylic was shown to increase measured impedance readings by a factor of 4x as the ratio of the distance between the sensing electrodes to the distance between the bioimpedance probe and acrylic reached 1:3. The average parasitic capacitance for the circuit presented was found to be 712 ± 128 pF, and the analytic compensation method was shown to be able to minimize this effect on the BIS measurements. Measurements of porcine spleen tissue showed close correlation with experimental results reported in published articles. This research presents the successful design and evaluation of a BIS instrument. Specifically, robust measurements were obtained by implementing a DC-stabilized current source, investigating probe-material proximity issues and compensating for parasitic capacitance. These strategies were shown to provide tissue measurements comparable with published literature.
  • 机译 截肢者测试协议动力型胫骨假体设备的结果和分析
    摘要:A powered ankle-foot prothesis and its control system were previously designed and built. To evaluate this prosthesis, amputee subject testing was performed. The testing results are analyzed and compared between the powered prosthesis, passive prosthesis, and able-bodied gait. Qualitative comparison showed the prosthesis achieved the design objectives. During stance phase, active ankle moment was generated in the powered prosthesis before push-off to help the amputee walk more naturally. During swing phase, the powered prosthesis was able to move to natural position to achieve foot clearance. However, the prosthesis is slightly under powered compared with the able-bodied ankle.
  • 机译 用于诱发局部体温过低的头颈支撑装置
    摘要:The present work describes the design of a device/system intended to induce local mild hypothermia by simultaneously cooling a patient's head and neck. The therapeutic goal is to lower the head and neck temperatures to 33–35 °C, while leaving the core body temperature unchanged. The device works by circulating a cold fluid around the exterior of the head and neck. The head surface area is separated into five different cooling zones. Each zone has a cooling coil and can be independently controlled. The cooling coils are tightly wrapped concentric circles of tubing. This design allows for a dense packing of tubes in a limited space, while preventing crimping of the tubing and minimizing the fluid pressure head loss. The design in the neck region also has multiple tubes wrapping around the circumference of the patient's neck in a helix. Preliminary testing indicates that this approach is capable of achieving the design goal of cooling the brain tissue (at a depth of 2.5 cm from the scalp) to 35 °C within 30– 40 min, without any pharmacologic or circulatory manipulation. In a comparison with examples of current technology, the device has shown the potential for improved cooling capability.
  • 机译 在间充质干细胞衍生的心脏瓣膜组织工程中模拟振荡器流动和动态力学条件对致密结缔组织形成的作用
    摘要:
  • 机译 经导管主动脉瓣展开配置对血流动力学的影响
    摘要:
  • 机译 在脉冲复制器中模拟主动脉瓣假体的动力学:数值方法和初步经验
    摘要:
  • 机译 确定患者特定的全膝关节置换负荷的计算框架
    摘要:The purpose of this work is to describe a computational framework for predicting total knee arthroplasty loads which are necessary for accurate preclinical testing of implant designs. Inputs required include patient knee joint kinematics, and implant type, size, and physiological alignment. Computational models used in the framework include the calculation of knee joint kinematics and kinetics, prediction of the contact path, a model to determine muscle forces, and a force model to obtain parametric solutions for implant forces. The resulting knee implant forces have been validated in two studies, and in both the model accurately predicted differences in knee joint loading. To date, implant contact forces have been predicted for 35 patients with four different implant types. Forces have been calculated for walking, chair, and stair activities.
  • 机译 新型手持式参考点压痕仪的应用测量骨材料强度
    摘要:A novel, hand-held Reference Point Indentation (RPI) instrument, measures how well the bone of living patients and large animals resists indentation. The results presented here are reported in terms of Bone Material Strength, which is a normalized measure of how well the bone resists indentation, and is inversely related to the indentation distance into the bone. We present examples of the instrument's use in: (1) laboratory experiments on bone, including experiments through a layer of soft tissue, (2) three human clinical trials, two ongoing in Barcelona and at the Mayo Clinic, and one completed in Portland, OR, and (3) two ongoing horse clinical trials, one at Purdue University and another at Alamo Pintado Stables in California. The instrument is capable of measuring consistent values when testing through soft tissue such as skin and periosteum, and does so handheld, an improvement over previous Reference Point Indentation instruments. Measurements conducted on horses showed reproducible results when testing the horse through tissue or on bare bone. In the human clinical trials, reasonable and consistent values were obtained, suggesting the Osteoprobe® is capable of measuring Bone Material Strength in vivo, but larger studies are needed to determine the efficacy of theinstrument's use in medical diagnosis.
  • 机译 纳米纹理化钛骨科螺钉的机械性能
    摘要:In this work, we modified the topography of commercial titanium orthopedic screws using electrochemical anodization in a 0.4 wt% hydrofluoric acid solution to produce titanium dioxide nanotube layers. The morphology of the nanotube layers were characterized using scanning electron microscopy. The mechanical properties of the nanotube layers were investigated by screwing and unscrewing an anodized screw into several different types of human bone while the torsional force applied to the screwdriver was measured using a torque screwdriver. The range of torsional force applied to the screwdriver was between 5 and 80 cN · m. Independent assessment of the mechanical properties of the same surfaces was performed on simple anodized titanium foils using a triboindenter. Results showed that the fabricated nanotube layers can resist mechanical stresses close to those found in clinical situations.
  • 机译 可高压灭菌的可控套管手动展开装置:设计和精度分析
    摘要:Accessing a specific, predefined location identified in medical images is a common interventional task for biopsies and drug or therapy delivery. While conventional surgical needles provide little steerability, concentric tube continuum devices enable steering through curved trajectories. These devices are usually developed as robotic systems. However, manual actuation of concentric tube devices is particularly useful for initial transfer into the clinic since the Food and Drug Administration (FDA) and Institutional Review Board (IRB) approval process of manually operated devices is simple compared to their motorized counterparts. In this paper, we present a manual actuation device for the deployment of steerable cannulas. The design focuses on compactness, modularity, usability, and sterilizability. Further, the kinematic mapping from joint space to Cartesian space is detailed for an example concentric tube device. Assessment of the device’s accuracy was performed in free space, as well as in an image-guided surgery setting, using tracked 2D ultrasound.
  • 机译 用于主动脉瓣置换的自扩张支架和输送系统
    摘要:Currently, aortic valve replacement procedures require a sternotomy and use of cardiopulmonary bypass (CPB) to arrest the heart and provide a bloodless field in which to operate. A less invasive alternative to open heart surgery is transapical or transcatheter aortic valve replacement (TAVR), already emerging as a feasible treatment for patients with high surgical risk. The bioprosthetic valves are delivered via catheters using transarterial or transapical approaches and are implanted within diseased aortic valves. This paper reports the development of a new self-expanding stent for minimally invasive aortic valve replacement and its delivery device for the transapical approach under real-time magnetic resonance imaging (MRI) guidance. Made of nitinol, the new stent is designed to implant and embed a commercially available bioprosthetic aortic valve in aortic root. An MRI passive marker was affixed onto the stent and an MRI active marker to the delivery device. These capabilities were tested in ex vivo and in vivo experiments. Radial resistive force, chronic outward force, and the integrity of bioprosthesis on stent were measured through custom design dedicated test equipment. In vivo experimental evaluation was done using a porcine large animal model. Both ex vivo and in vivo experiment results indicate that the self-expanding stent provides adequate reinforcement of the bioprosthetic aortic valve and it is easier to implant the valve in the correct position. The orientation and positioning of the implanted valve is more precise and predictable with the help of the passive marker on stent and the active marker on delivery device. The new self-expanding nitinol stent was designed to exert a constant radial force and, therefore, a better fixation of the prosthesis in the aorta, which would result in better preservation of long-term heart function. The passive marker affixed on the stent and active marker embedded in the delivery devices helps to achieve precise orientation and positioning of the stent under MRI guidance. The design allows the stent to be retracted in the delivery device with a snaring catheter if necessary. Histopathology reports reveal that the stent is biocompatible and fully functional. All the stented bioprosthesis appeared to be properly seated in the aortic root.
  • 机译 经导管二尖瓣心脏瓣膜框架的基于仿真的设计和评估
    摘要:In certain populations, open heart surgery to replace a diseased mitral valve is not an option, leaving percutaneous delivery a viable alternative. However, a surgical transcatheter based delivery of a metallic support frame incorporating a tissue derived valve puts considerable constraints on device specifications. Expansion to a large diameter from the catheter diameter without mechanical fracture involves advanced device design and appropriate material processing and selection. In this study, a new frame concept is presented with a desirable feature that incorporates wings that protrude during expansion to establish adequate fixation. Expansion characteristics of the design in relation to annulus fixation were quantified through finite element analysis predictions of the frame wing span and angles. Computational modeling and simulation was used to identify many favorable design features for the transcatheter mitral valve frame and obtain desired expansion diameters (35–45mm), acceptable radial stiffness (2.7N/mm), and ensure limited risk of failure based on predicted plastic deformations.