首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Comparison of automated Difco ESP blood culture system with biphasic BBL Septi-Chek system for detection of bloodstream infections in pediatric patients.
【2h】

Comparison of automated Difco ESP blood culture system with biphasic BBL Septi-Chek system for detection of bloodstream infections in pediatric patients.

机译:自动化Difco ESP血液培养系统与双相BBL Septi-Chek系统在儿科患者中检测血流感染的比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We compared the Difco ESP 384 blood culture system with the pediatric Septi-Chek system for the detection of bloodstream infections in pediatric patients. A total of 10,762 blood culture sets included an ESP aerobic bottle and a Septi-Chek bottle. From these cultures, a total of 278 organisms classified as probable pathogens were isolated, including 237 from ESP bottles and 221 from Septi-Chek bottles. This difference was not statistically significant. More organisms classified as possible contaminants were also isolated from ESP bottles (for ESP, 480 bottles; for Septi-Chek, 418 bottles; P < 0.01). The time to detection was shorter for probable pathogens isolated from ESP bottles (median times for organisms isolated from both systems: ESP, 14.0 h; Septi-Chek, 34.5 h; P < 0.001). The proportions of all probable pathogens detected by 24 and 48 h after inoculation were 78 and 96%, respectively, for ESP compared with 31 and 74%, respectively, for Septi-Chek. The time to final identification was also shorter for organisms grown in ESP bottles (median times for organisms isolated from both systems: ESP, 48.8 h; Septi-Chek, 58.5 h; P < or = 0.001). A subset of 4,442 cultures also included an ESP anaerobic bottle in addition to an ESP aerobic bottle and a Septi-Chek bottle. There were no significant differences in the recovery of probable pathogens by any of the possible two bottle combinations, but five anaerobic pathogens were recovered only in the anaerobic bottle.(ABSTRACT TRUNCATED AT 250 WORDS)
机译:我们将Difco ESP 384血液培养系统与小儿Septi-Chek系统进行了比较,以检测小儿患者的血流感染。总共10,762套血液培养装置包括一个ESP有氧瓶和一个Septi-Chek瓶。从这些培养物中,总共分离出了278种被归类为可能病原体的生物,包括237种来自ESP瓶和221种来自Septi-Chek瓶。这种差异在统计学上不显着。还从ESP瓶中分离出了更多分类为可能污染物的生物(对于ESP,为480瓶;对于Septi-Chek,为418瓶; P <0.01)。从ESP瓶中分离出可能的病原体的检测时间更短(从两个系统分离出的生物体的中位时间:ESP,14.0 h; Septi-Chek,34.5 h; P <0.001)。 ESP接种后24和48 h检出的所有可能病原体的比例分别为ESP的78%和96%,而Septi-Chek分别为31%和74%。对于在ESP瓶中生长的生物,最终鉴定的时间也更短(从两个系统分离的生物的中值时间:ESP,48.8小时; Septi-Chek,58.5小时; P <或= 0.001)。除ESP好氧瓶和Septi-Chek瓶外,还有4,442种培养物的子集还包括ESP厌氧瓶。两种可能的组合中任何一种的可能病原体回收率均无显着差异,但仅在厌氧瓶中回收了五种厌氧病原体。(摘要截断为250个字)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号