Automation of Vapour Pressure Osmometry measurements

机译:蒸气压渗透压测量自动化

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A program has been developed for the control of Vapour Pressure Osmometry (VPO) measurements. The output signal of a Vapour Pressure Osmometer is read by an A/D converter card installed in one of the expansion slots of a PC microcomputer. The stability of the measurements is checked by analysing the first derivative of the smoothed signals, which is calculated in real time. Sets of repeated measurements are carried out under the supervision of a computer program as a check for their reproducibility. When the set is ended the program calculates the average and its standard deviation.The program is particularly valuable for evaluating VPO measurements for solution equilibria studies. This interfacing strategy may be applied to any kind of technique in which the time stability of the signals is the basis for defining measurement stability. The automated VPO has other advantages, including low cost and time saving.
机译:已经开发了用于控制蒸汽渗透压(VPO)测量的程序。蒸气压渗透计的输出信号由安装在PC微型计算机扩展插槽之一中的A / D转换卡读取。通过分析实时计算的平滑信号的一阶导数来检查测量的稳定性。多套重复测量在计算机程序的监督下进行,以检查其可重复性。设置结束后,程序将计算平均值及其标准偏差。该程序对于评估溶液平衡研究的VPO测量值特别有价值。该接口策略可以应用于任何类型的技术,在这些技术中,信号的时间稳定性是定义测量稳定性的基础。自动化VPO具有其他优势,包括低成本和节省时间。