Effect of Body Position on Limb Lead Electrocardiographic Findings in Sedated Cynomolgus Macaques (Macaca fascicularis)

机译:体位对镇静食蟹猕猴(Macaca fascicularis)肢体铅心电图检查结果的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Electrocardiograms (ECGs) often are collected from sedated cynomolgus macaques (Macaca fascicularis) in drug safety studies to support investigational new drug applications. ECGs are evaluated either manually or electronically, and the quality of the ECG tracing can affect the quality of that evaluation. The body position of the subject sometimes is manipulated to eliminate noise or clarify ECG complex morphology, and typically multiple technicians collect ECG data over time. Both factors—body position and multiple technicians—could affect ECG quality. This study was designed to determine whether body position or multiple technicians affects heart rate, mean electrical axis, or ECG parameters (RR interval, P wave duration, PR interval, QRS duration, QT interval (uncorrected and rate-corrected by using the Bazett [QTcb] and Fridericia [QTcf] formulas), P wave amplitude, R wave amplitude, T wave height, T wave height negative, and ST segment elevation). The results reveal minimal (coefficient of variation [CV] less than 10%) within-animal variation between body positions (ventral, dorsal, right or left lateral), with the exception of P wave amplitude (17.5%), R wave amplitude (23.7%), and ST segment elevation (43%). Minimal variation in ECG parameters (no more than 7%) was detected between technicians, across animals, and across body positions. These findings suggest that neither a change in body position to increase the quality of an ECG tracing nor the use of multiple technicians significantly affect the evaluation of quantitative ECG parameters, especially QTcb (0.1% CV) and QTcf (1.3% CV).
机译:心电图(ECG)通常是在药物安全性研究中从镇静的食蟹猕猴(Macaca fascicularis)收集的,以支持新药的研究用途。 ECG可以通过手动或电子方式进行评估,并且ECG追踪的质量可能会影响评估的质量。有时会操纵对象的身体位置以消除噪音或弄清ECG复杂的形态,通常,随着时间的推移,多个技术人员会收集ECG数据。身体位置和多个技术人员这两个因素都可能影响心电图质量。这项研究旨在确定身体姿势或多个技术人员是否会影响心率,平均电轴或ECG参数(RR间隔,P波持续时间,PR间隔,QRS持续时间,QT间隔(未使用Bazett进行校正和速率校正)[ QTcb]和Fridericia [QTcf]公式),P波幅度,R波幅度,T波高度,T波高度负和ST段高程)。结果显示,除P波振幅(17.5%),R波振幅((17.5%)以外,身体位置(腹,背,右或左外侧)之间的动物内变化最小(变异系数[CV]小于10%)。 23.7%)和ST段抬高(43%)。在技​​术人员之间,动物之间以及身体位置之间检测到的ECG参数变化最小(不超过7%)。这些发现表明,改变体位以增加心电图描记质量或使用多名技术人员都不会显着影响定量心电图参数的评估,尤其是QTcb(0.1%CV)和QTcf(1.3%CV)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号