摘要

>Aim: Malfixed miniplates can impair fracture healing, and the screw pilot holes may widen during repeated fixation trials. This in vitro study explored the extent to which screw fixation of mandibular angle fractures could be improved by augmenting the drilling holes with polymethylmethacrylate (PMMA).>Materials and Methods: We measured stabilization by recording specimen displacement under a vertical force of 50 N applied using a hydraulic tester. We included 20 hemimandibles from sheep (average weight 40 kg). The specimens were randomly divided into two groups of 10 and pilot holes were created in the angulus region using a drill 1.2 mm in diameter. Next, we performed osteotomies simulating angulus fracture repair. In group 1, the fracture site was fixed using non-compression miniplates and four screws were inserted to the maximal possible extent employing a mechanical screwdriver. In group 2, the pilot drill holes were filled with PMMA prior to miniplate fixation. Then vertical forces of 50 N were applied to the molar region and the displacements were measured. The Shapiro-Wilks test was used to compare the two groups.>Result: The maximum average displacement in the experimental group was significantly lower than that in the control group (p=0.026). Thus, PMMA-augmented screws better stabilized bone, affording reliable fixation.
机译:>目标:固定不正确的微型钢板会损害骨折愈合,并且在反复进行固定试验期间,螺钉导向孔可能会变宽。这项体外研究探讨了通过使用聚甲基丙烯酸甲酯(PMMA)扩大钻孔可改善下颌角骨折的螺钉固定的方法。>材料与方法:使用液压测试仪施加50 N的力。我们纳入了20种来自绵羊的半固定动物(平均体重40公斤)。将样本随机分为两组,每组10个,并使用直径1.2毫米的钻头在角区域形成导向孔。接下来,我们进行了模拟小角膜骨折修复的截骨术。在第1组中,使用非加压微型固定板固定骨折部位,并使用机械螺丝刀最大程度地插入四个螺钉。在第2组中,在微型板固定之前先用PMMA填充先导钻孔。然后向磨牙区域施加50 N的垂直力,并测量位移。使用Shapiro-Wilks检验对两组进行比较。>结果:实验组的最大平均位移明显低于对照组(p = 0.026)。因此,PMMA增强螺钉可以更好地稳定骨骼,提供可靠的固定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号