首页> 美国卫生研究院文献>Interventional Cardiology Review >Expert Opinion: Optimising Stent Deployment in Contemporary Practice: The Role of Intracoronary Imaging and Non-compliant Balloons
【2h】

Expert Opinion: Optimising Stent Deployment in Contemporary Practice: The Role of Intracoronary Imaging and Non-compliant Balloons

机译:专家意见:优化当代实践中的支架部署:冠状动脉内成像和不顺应性球囊的作用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Final stent dimensions remain an important predictor of restenosis, target vessel revascularisation (TVR) and subacute stent thrombosis (ST), even in the drug-eluting stent (DES) era. Stent balloons are usually semi-compliant and thus even high-pressure inflation may not achieve uniform or optimal stent expansion. Post-dilatation with non-compliant (NC) balloons after stent deployment has been shown to enhance stent expansion and could reduce TVR and ST. Based on supporting evidence and in the absence of large prospective randomised outcome-based trials, post-dilatation with an NC balloon to achieve optimal stent expansion and maximal luminal area is a logical technical recommendation, particularly in complex lesion subsets.
机译:即使在药物洗脱支架(DES)时代,最终的支架尺寸仍然是再狭窄,靶血管血运重建(TVR)和亚急性支架血栓形成(ST)的重要预测指标。支架球囊通常是半顺应性的,因此即使高压充气也可能无法实现均匀或最佳的支架扩张。研究表明,在支架部署后使用不顺应性(NC)球囊进行扩张后,可以增强支架的扩张能力,并可以降低TVR和ST。基于支持证据,并且在没有大型的,基于前瞻性,基于随机结果的试验的情况下,采用NC球囊进行扩张以实现最佳的支架扩张和最大的管腔面积是合理的技术建议,尤其是在复杂病变亚组中。