An articulated ankle external fixation system that can be aligned with the ankle axis.

机译:可以与踝关节轴对齐的铰接式踝关节外固定系统。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Aligning an articulated ankle external fixator with the ankle axis located using a mechanical axis finder has been shown to preserve normal ankle joint kinematics while the fixed hinge device is attached. However, several problems exist preventing the clinical application of this finding for fractures of the tibial plafond. We initiated a series of studies to resolve these issues. First, the accuracy of the mechanical axis finder in biological systems was quantified by comparing it to that of a computationally derived helical axis. Second, a prototype fixator design was developed in the biomechanics lab to increase the versatility of intraoperative fixator placement. Finally, a radiographic method of locating the ankle axis was developed which is based on talar morphology independent of the fractured tibia. The prototype fixator has been accurately aligned along the ankle axis in cadaveric specimens using this method. Open reduction and internal fixation (ORIF) is the accepted method of treatment for tibial plafond fractures. It holds the advantage of sufficient fracture fixation to permit early joint motion. Good results have been reported using this method, but some authors have reported complication rates up to 50%. The wide surgical approaches required, in conjunction with preexisting soft tissue injury, are thought to significantly increase the risk of soft tissue complications. In response to these problems, many investigators are beginning to utilize external fixation as an alternate treatment modality. One external fixation system which has shown particularly good results is a monolateral cross-ankle articulated fixator (Orthofix SRL., Verona, Italy) which allows motion at the ankle joint as the plafond fracture is healing (Figure 1).(ABSTRACT TRUNCATED AT 250 WORDS)
机译:业已表明,使用固定式铰链装置将铰接的踝关节外部固定器与使用机械式轴线查找器定位的踝关节轴线对齐后,可以保持正常的踝关节运动学。但是,存在一些问题阻碍了这一发现在胫骨平台骨折中的临床应用。我们发起了一系列研究来解决这些问题。首先,通过将其与生物计算得出的螺旋轴的精度进行比较,来量化生物系统中机械轴的精度。其次,在生物力学实验室中开发了原型固定器设计,以增加术中固定器放置的多功能性。最后,开发了一种基于脚距形态而独立于胫骨骨折的定位脚踝轴的射线照相方法。使用这种方法,已将原型固定器沿尸体标本的踝轴精确对齐。切开复位内固定(ORIF)是胫骨平台骨折的公认治疗方法。它具有充分固定骨折以允许早期关节运动的优点。使用这种方法已报告了良好的结果,但一些作者报告的并发症发生率高达50%。人们认为,所需的广泛手术方法与先前存在的软组织损伤相结合,会大大增加软组织并发症的风险。针对这些问题,许多研究者开始使用外固定作为替代治疗方式。一种表现出特别好的效果的外固定系统是单侧跨踝关节固定器(Orthofix SRL。,意大利维罗纳),可以在fracture骨骨折愈合期间在踝关节处运动(图1)。(摘要摘录于250话)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号