首页> 美国卫生研究院文献>Iranian Endodontic Journal >Comparison of Cytotoxicity of Three Dentin Bonding Systems with Two Thicknesses of Dentin Barrier on L929 Cell Line
【2h】

Comparison of Cytotoxicity of Three Dentin Bonding Systems with Two Thicknesses of Dentin Barrier on L929 Cell Line

机译:三种具有两种厚度的牙本质屏障的牙本质结合系统对L929细胞的细胞毒性比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>INTRODUCTION: Along with introduction of dentin bonding agents (DBA), their clinical use as lining materials is increasing rapidly. Since remaining dentinal thickness (RDT) has always been a concern for cytopathic effect of restorative materials, its effect on reduction of cytotoxicity of these materials especially DBAs is critical. The purpose of this study was to evaluate and compare the cytotoxicity of three dentin bonding systems, belonged to the 4th, 5th and 6th generation of DBAs on L929 cell line. >MATERIALS AND METHODS: Thirty human premolar teeth were included. Class I cavity preparations were prepared on occlusal surfaces. After crown separation, a flat dentinal surface was provided and RDT (remaining dentinal thickness) was adjusted at 0.5 and 1.5 mm. Then, cavities were treated in three groups with experimental DBAs: Group 1: Scotchbond multipurpose, Group 2: Excite, Group 3: AdheSE. Blue inlay wax sealed the cavities. Crowns were immersed in culture medium for 24 hours and the cytotoxicity of the resultant toxic medium was measured quantitatively with MTT assay in 4 serial dilutions. Data were analyzed with ANOVA and Tukey’s test at 95% significance level. >RESULTS: MTT assay determined that only in neat dilution of 0.5 mm RDT, cell changes were significantly different from control. Besides, no significant differences were found between the three experimental DBAs regarding cytotoxic effect on L929 cell line. >CONCLUSION: Considering the limitations of an in vitro study, if the RDT is less than 0.5 mm in vivo, regardless of the type of DBA, destructive cellular changes in pulp tissue can be expected.
机译:>引言:随着牙本质粘接剂(DBA)的引入,它们作为衬里材料的临床应用正在迅速增加。由于剩余的牙本质厚度(RDT)一直是修复材料的细胞病变作用的关注因素,因此其对降低这些材料(尤其是DBA)的细胞毒性的作用至关重要。这项研究的目的是评估和比较属于第4 ,5 和6 的三种牙本质结合系统的细胞毒性。 L929细胞系上生成DBA。 >材料和方法:其中包括30颗人类前磨牙。在咬合面上准备I类腔准备。牙冠分离后,提供平坦的牙本质表面,并将RDT(牙本质剩余厚度)调整为0.5和1.5 mm。然后,用实验性DBA将空腔分为三组:第1组:Scotchbond多用途,第2组:激发,第3组:AdheSE。蓝色镶嵌蜡密封了空腔。将牙冠浸入培养基中24小时,并用4种系列稀释液用MTT法定量测定所得毒性培养基的细胞毒性。使用ANOVA和Tukey检验以95%的显着性水平分析数据。 >结果:MTT分析确定,仅在0.5 mm RDT的纯稀释液中,细胞变化与对照相比有显着差异。此外,在对L929细胞系的细胞毒性作用方面,三个实验DBA之间没有发现显着差异。 >结论:考虑到体外研究的局限性,如果体内RDT小于0.5 mm,则无论DBA的类型如何,都可以预期髓组织中的破坏性细胞变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号