Adequate stem alignment is essential for the success of Total Hip Arthroplasty (THA) to avoid dislocation and impingement. One factor that has not been sufficiently investigated so far is the stem tilting in the sagittal plane, which has an influence on the position of the centre of the femoral head and thus also on prosthesis torsion. We aimed to evaluate sagittal stem position using 3D-CTs in patients with THA and to develop a mathematical-geometrical model to simulate the functional correlation between sagittal stem tilting and the influence on functional anteversion. Thirty patients with THA underwent a CT-scan. By 3D-reconstruction of the CT-data, femoral-/prosthesis-axis, torsion and sagittal tilt were determined. In accordance with the position of the femoral and prosthesis axes, the rotatory (rAV) (surgically adjusted) and functional (depending on sagittal tilt) anteversion (fAV) was measured. A three dimentional-coordinate transformation was also performed using the Euler-angles to derive a mathematical-geometrical correlation between sagittal stem tilting and corresponding influence on anteversion. The mean rAV was 8° (-11.6 - 26°), the fAV 18° (6.2 - 37°), and the difference 10° (8.8 - 18°). The mean degree of stem tilting was 5.2° (0.7 - 9°) anterior towards the femoral axis. The individually measured parameters are reflected in the mathematical-geometrical model. Depending on the extent of the sagittal deviation, a clear influence on the torsion emerges. For example, a stem implanted at a 15° anteverted angle with a sagittal tilt by two degrees towards anterior results in a fAV of 20°. A clear association between the sagittal stem alignment and the impact on the fAV was demonstrated. Hence, the rotatory anteversion intended by the surgeon may be functionally significantly different. This might pose an increased risk of dislocation or impingement. The sagittal tilt of the prosthesis should therefore be considered in the context of impingement and dislocation diagnosis. In this respect, we recommend a 3D-analysis of stem alignment.
机译:充分的茎对齐对于全髋关节置换术(THA)的成功至关重要,以避免脱位和撞击。迄今为止尚未充分研究的一个因素是茎在矢状平面中的倾斜,这会影响股骨头中心的位置,进而也会影响假体的扭转。我们旨在使用3D-CT对THA患者进行矢状茎位置评估,并建立数学几何模型来模拟矢状茎倾斜与功能前倾之间的功能相关性。 30名THA患者接受了CT扫描。通过3D重建CT数据,确定股骨/假体轴,扭转和矢状倾角。根据股骨和假体轴的位置,测量了旋转(rAV)(手术调整)和功能性(取决于矢状面倾斜)前倾(fAV)。还使用欧拉角进行了三维坐标​​变换,以得出矢状茎倾斜与相应的前倾影响之间的数学几何关系。平均rAV为8°(-11.6-26°),fAV为18°(6.2-37°),差值为10°(8.8-18°)。股骨柄向股骨轴的平均倾斜度为5.2°(0.7-9°)。单独测量的参数反映在数学几何模型中。取决于矢状偏离的程度,对扭转产生明显的影响。例如,以15°的倒角角度植入的茎,矢状向前方倾斜2度,则fAV为20°。矢状茎排列与对fAV的影响之间存在明确的关联。因此,外科医生想要的旋转前倾在功能上可能会明显不同。这可能会增加脱臼或撞击的风险。因此,应在撞击和脱位诊断的背景下考虑假体的矢状倾斜。在这方面,我们建议对茎对齐进行3D分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号