首页> 美国卫生研究院文献>Journal of Biomedical Research >Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments
【2h】

Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments

机译:机械制备三台镍钛旋转仪后的锥形根管锥形束计算机断层扫描分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Cone beam computed tomography is a 3-dimensional high resolution imaging method. The purpose of this study was to compare the effects of 3 different NiTi rotary instruments used to prepare curved root canals on the final shape of the curved canals and total amount of root canal transportation by using cone-beam computed tomography. A total of 81 mesial root canals from 42 extracted human mandibular molars, with a curvature ranging from 15 to 45 degrees, were selected. Canals were randomly divided into 3 groups of 27 each. After preparation with Protaper, Revo-S and Hero Shaper, the amount of transportation and centering ability that occurred were assessed by using cone beam computed tomography. Utilizing pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis program. Canals were metrically assessed for changes (surface area, changes in curvature and transportation) during canal preparation by using software SimPlant; instrument failures were also recorded. Mean total widths and outer and inner width measurements were determined on each central canal path and differences were statistically analyzed. The results showed that all instruments maintained the original canal curvature well with no significant differences between the different files (P = 0.226). During preparation there was failure of only one file (the protaper group). In conclusion, under the conditions of this study, all instruments maintained the original canal curvature well and were safe to use. Areas of uninstrumented root canal wall were left in all regions using the various systems.
机译:锥束计算机断层摄影是一种3维高分辨率成像方法。这项研究的目的是通过使用锥形束计算机断层扫描技术,比较三种用于制备弯曲根管的NiTi旋转器械对弯曲根管最终形状和根管运输总量的影响。从42个提取的人类下颌臼齿中选择了总共81条中根管,其曲率范围为15至45度。运河被随机分为3组,每组27条。用Protaper,Revo-S和Hero Shaper进行准备后,通过使用锥形束计算机断层摄影术评估发生的运输量和对中能力。利用仪器前后的X射线照片,使用计算机图像分析程序确定管曲率的矫直。通过使用SimPlant软件,以运河形式对运河的变化进行了评估(表面积,曲率和运输的变化);仪器故障也被记录下来。在每个中央运河路径上确定平均总宽度以及外部和内部宽度测量值,并对差异进行统计分析。结果表明,所有器械均能很好地保持原有的根管曲率,不同锉之间无明显差异(P = 0.226)。在准备过程中,只有一个文件(protaper组)失败。综上所述,在本研究条件下,所有器械均能很好地保持原有的根管弯曲度,并且使用安全。使用各种系统在所有区域中保留未器械化的根管壁区域。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号